Care And Maintenance; Cleaning The Press Tools - Viega Pressgun Picco Instructions For Use Manual

Press machine set
Table of Contents

Advertisement

3.6

Care and maintenance

3.6.1

Cleaning the press tools

Press machine
Pressgun Picco press machine set
Fault
Cause
Actuating the Start
The press machine is
button does not
not switched on.
trigger pressing.
The battery is too
weak.
The battery or mains
adapter is not prop‐
erly inserted.
The mains cable of
the mains adapter is
not connected to the
mains.
The power supply is
not correct.
Contact an authorised service partner if the press machine does not
start after carrying out the measures above.
The tools are subject to normal wear and tear; for this reason, they must
be maintained in regular intervals. Only service partners authorised by
Viega may service and maintain the tools. See
tion and maintenance' on page 19.
NOTICE!
Damage due to fluids!
Make sure that no fluids get inside the press machine.
Never dip the press machine into fluids.
Requirements:
The press machine is not energised (disconnected from the mains or
n
rechargeable battery has been removed).
No press jaw is inserted.
n
Wipe the press machine down with a slightly damp cloth.
Clean the press rolls of the roller head dry and then treat with main‐
tenance oil (art. no. 667 924).
Handling
Solution
Press the On/Off
button. The green
LED is lit.
Fully charge the bat‐
tery.
Check it is correctly
located in the
mounting bracket.
Connect it to the
power supply.
Establish the power
supply as specified by
the manufacturer.
Ä Chapter 3.6.3 'Inspec‐