Operation Manual / 4 Product description / A100-L
4
Monitoring during operation
4.3

Low pressure measurement at the filter silencer

4.3.1
Introduction
The low pressure measurement with a U-tube manometer is used for the following purposes:
 During acceptance test of the engine: Measurement of the correction factor for the calcula-
tion of the turbocharger efficiency
 When using a filter mat: An increased pressure loss indicates an increase in the fouling of
the filter material.
4.3.2
U-tube manometer at the filter silencer
Figure 10: U-tube manometer at the filter silencer
81000
81050
A [mm H
O]
2
If the turbocharger is operated at maximum engine power and pressure loss (A) reaches the
value of 200 mm H
O:
2
Clean filter mat.
Reading of pressure loss
For simple reading of the pressure loss (A), the dipstick at the U-tube ma-
nometer can be pulled out to the level of the lower water level.
NOTICE
Better readability of the U-tube manometer can be achieved by filling with
slightly coloured water.