ABB HT564586 Operation Manual page 55

Table of Contents

Advertisement

Operation Manual / 4 Product description / A100-L
4
Monitoring during operation
4.2.4
Replacing the speed sensor
Hot cable connector and hot speed sensor
Danger of burns. The cable connector and the speed sensor can reach tem-
peratures of more than 100 °C during operation.
WARNING
When disassembling the cable connector and speed sensor, wear safety
gloves.
Wear safety gloves to protect against thermal hazards.
Sealing of the speed sensor
The speed sensor is designed with a sealing lip and does not require a seal-
ing disc for assembly.
NOTICE
Figure 9: Replacing the speed sensor
Part number
A165-L
86505
M18x1.5
150 Nm
Table 9: Tightening torques (86505)
Reduce the engine performance to idling and then stop the engine. Pay attention to post-
lubrication (Stopping the engine [➙ 36]).
Switch off the lubricating oil supply to the turbocharger.
Disconnect the cable connector from the speed sensor.
Unscrew defective speed sensor.
Screw in new speed sensor to the stop.
Connect cable connector (86515) with the speed sensor (86505)
Switch on lubricating oil supply to the turbocharger.
© Copyright 2016 ABB. All rights reserved.
A170-L
A175-L
M18x1.5
M18x1.5
150 Nm
150 Nm
HZTL4034_EN
A180-L
A185-L
M27x2
M27x2
320 Nm
320 Nm
Revision F
Page 25 / 111
A190-L
M27x2
320 Nm
June 2016