SAFETY PRECAUTIONS Important Safety Instructions Please read the following precautions carefully before using this equipment. This unit contains high voltage components which, may expose you to the risk of electric shock. Do not open the enclosure without isolating the signal and supply sources. Ensure that these sources have been isolated for at least 5 minutes before entering the enclosure.
INSTALLATION - MOUNTING Fix the unit to a vertical wall using the screws provided. Ensure that the unit is level and positioned no more than 2 metres above the base of the product, which is to be dispensed. Important notes. Maximum recommended suction and delivery tubes - 2 metres Minimum tube size - 8x11mm Screw pitch/Drilling diagram - on next page...
INSTALLATION - WIRING 1 In most cases, the interface board or solenoids in the host machine will have a common (i.e their negative terminals are all linked by a common wire). The switches S1 & S2 can be left switched to common (up position), and the single(common) wire taken to the B rail.
INSTALLATION - WIRING 2 In some cases, the interface board or solenoids in the hose machine are not common. For example: The softener solenoid on some machines is not linked via a common wire to the other solenoids. If this is the case, the signal must be isolated from the common B rail on the Board. This is done by Switching the appropriate switch (S1 &...
PROGRAMMING - CONTROLS PROGRAMMING - KEY TO INSTRUCTIONS Throughout the instructions: Throughout the instructions, SIGNAL there are several screens ACCEPTANCE TIME If a button or buttons are which are highlighted 00 SECONDS BLUE shown in then BOLD. they must be pressed to progress to the next stage.
Use the UP and DOWN keys to scroll through the language options. Press the FWD/ACCEPT key to select the displayed 00000 ENTER CODE TO ENTER CODE TO CHANGE LANGUAGE CHANGE LANGUAGE BRIGHTWELL ---- 1--- ENTER CODE TO CHANGE LANGUAGE ENGLISH FRANCAIS...
FLOW DIAGRAM - INSTRUCTIONS ACCESSING MODES SELECT 0000 ENTER CODE TO RELAY MODE CHANGE UNIT MODE UNIT MODE ---- STANDARD MODE Brightwell SELECT FLUSH VALVE MODE UNIT MODE DURING & AFTER STANDARD MODE SELECT FLUSH VALVE MODE UNIT MODE DURING & AFTER...
FLOW DIAGRAM - INSTRUCTIONS STANDARD MODE PROGRAM 01 INPUT 01 PUMP 01 INPUT 01 PUMP 01 PROGRAM 01 SET INPUT 02 SET INPUT 01 SET DELAY TIME SET RUN TIME Program SET PUMP 01 ENABLE 00 MIN 00 SECS 00 MIN 00 SECS PROGRAM 01 PROGRAM 01 PROGRAM 01...
FORMULA SELECT The BrightLogic laundry Formula Select module (optional) allows remote selection of up to 20 different wash programs, program names can be displayed by uploading via the computer program. The Formula Select module can also be used to prime and stop the pumps. The desired program must be selected, using the UP and DOWN keys on the module and pressing enter, before beginning the wash cycle.