Larson Electronics GSLEDIP6-C1D2 Instruction Manual

4 watt led light fixtures for hazardous location illumination 6.5" low voltage light fixture

Advertisement

4 Watt LED Light Fixtures for Hazardous Location Illumination
Thank you for your purchase of the Larson Electronics GSLEDIP6-C1D2.
WARNING:
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CRITICAL SAFETY INSTRUCTIONS:
INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY
RELEVANT LOCAL BUILDING CODES.
RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF FIXTURE'S ELECTRICAL
SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.
BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE FIXTURE'S RATED VOLTAGE.
TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP
OBJECTS. SUITABLE FOR DAMP LOCATIONS.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE. THE GSLEDIP6-C1D2 MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL
CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.
WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS
PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET,
CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE.
WARNING: MAKE SURE POWER IS TURNED OFF BEFORE STARTING THE
INSTALLATION OR PERFORMING ANY MAINTENANCE.
RISK OF FIRE/ELECTRIC SHOCK –
RISK OF PERSONAL INJURY –
RISK OF BURN –
ALLOW FIXTURE TO COOL BEFORE SERVICING.
WARNING:
USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE.
CORD IS INTENDED TO ALLOW OPERATORS TO EXTEND POWER TO EQUIPMENT WHEN STATIONARY OUTLETS ARE NOT
READILY AVAILABLE.
IMPROPER USE OF THIS CORD, PLUG, AND RECEPTACLE CAN LEAD TO SERIOUS INJURIES OR DEATH TO
PERSONNEL.
PERIODIC INSPECTION OF THE CORD IS NECESSARY.
THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY ARE FOUND,
THE CORD MUST BE REPLACED BEFORE RESUMING USE.
II. Warnings and Safety Ratings
I. Warnings
To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected and maintained by a qualified
electrician only, in accordance with all applicable electrical codes.
To avoid electric shock, be certain electrical power is OFF before and during installation and maintenance. Luminaire must be
connected to a wiring system with an equipment-grounding conductor.
Do NOT install fixture in any classified location where the marked operating temperature exceeds the ignition temperature of the
hazardous atmospheres.
Consult fixture nameplate for the suitability ambient temperature shown on the nameplate.
Refer to fixture nameplate for minimum supply wire temperature rating.
Verify that the supply voltage agrees with fixture rating as indicated on the nameplate.
All local and national electrical/building codes must be followed when installing this lighting fixture. For code interpretation, consult
your local authority.
Product must be used only with glass tubes intact and all cap threads fully engaged. Do NOT use if glass tubes are cracked or
damaged in any way.
Larson Electronics, LLC
6.5" Low Voltage Light Fixture
Instruction Manual
DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.
FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY.
Phone: (800) 369-6671
Fax: (903) 498-3364
GSLEDIP6-C1D2
www.larsonelectronics.com
THIS LINE
1 of 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GSLEDIP6-C1D2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Larson Electronics GSLEDIP6-C1D2

  • Page 1 IMPORTANT READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. THE GSLEDIP6-C1D2 MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY. WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS PRODUCT.
  • Page 2 IP54 Ingress Protection T3 Temperature Ratings The Larson Electronics GSLEDIP6-C1D2 is a low voltage hazardous location lighting solution approved for Class1 Division 2 environments and U.L. 1598 compliant for use in wet locations. This powerful LED strip light produces 221 lumens, operates from 12 or 24 VDC, and is suitable for a variety of applications.
  • Page 3 GSLEDIP6-C1D2 MOUNTING The GSLEDIP6-C1D2 hazardous location LED light is constructed of extruded aluminum with a tough powder coat finish for high strength and durability. The housing is IP54 rated, providing limited ingress protection against dusts, and l protection against light water spray such as rain. This design is weather resistant, suitable for indoor or outdoor applications, and ideal for areas where wetness or dusty conditions are commonly encountered.
  • Page 4 Inspect for good working condition prior to storage and before re-use. REPLACEMENT PARTS The GSLEDIP6-C1D2 is designed to provide years of reliable performance. Should the need for replacement parts arise, please contact Larson Electronics. THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS.