Download Print this page

Ritchie OmniFount 3 Installation Instructions Manual page 3

Advertisement

D. Riser Tube - Install a riser tube and extend it at least one foot below frost line or
down to horizontal underground water line. For optimum water line protection, use
the 12" diameter insulated Ritchie Thermal Tube, part numbers and sizes are shown
to the right. Tube opening must be kept clear.
NOTE: The supply line touching the riser tube is the most common cause of
the supply line freezing. Do not surround the supply line with insulation, wood,
or other foreign material. Any foreign material in the tube may cause frost to
migrate to the supply line causing it to freeze.
E. Mounting Platform - A concrete platform must be provided for all fountains. Use a minimum of 4" thick, (6"
recommended thickness), large enough to accommodate fountain, and additional 4" step (on top of the platform)
extending 18" out from each side of the unit. This will protect the unit from manure handling equipment, as well as
discouraging animals from defecating in the fountain. Extending the platform provides animals a place to stand
while drinking, consider the size of your animals when determining the dimensions of your platform. The concrete
step and platform should slope away from the fountain for drainage. A rough broom finish to concrete surface
provides better footing for livestock.
F. Hose Connection - Connect hose fitting to shut-off valve at top of concrete. Slip on barb fitting with furnished
clamps. Hose should not touch insulation or outside surface of fountain. Place the hose under the fountain as you
move the unit in place over the riser tube.
G. Preparing the bottom - Apply the provided foam weather stripping to the bottom of the unit, along the outside
edge of the fountain.
H. Anchoring Fountain –The OmniFount 5 & 10 have 6 molded hold-down pockets. The use of 3/8" x 5" stainless
steel expansion anchor bolts (not included) is recommended. Anchor bolts are available from Ritchie in a two pack,
part #16555. Large diameter fender washers are included and should be used with anchor bolt to prevent damage
to the plastic casing. Remove the side access panel to prepare for the remainder of the installation process.
OmniFount Large Series Instruction Manual
2
Ritchie Thermal Tube
Part #
Description
18158
1' Top Section
16417
2' Top Section
16612
4' Top Section
16416
2' Extension
August 13, 2022