Page 1
Installation Instructions for OmniFount 3, 5, 10 Congratulations, you have just purchased the finest watering fountain on the market. This unit is built to give you excellent service when properly installed and maintained. Please follow instructions carefully. Read and understand all instructions before installing.
OmniFount 3, 5 and 10 Installation Instructions A. Location - Putting the fountain in a location that offers protection from the wind will enhance the performance of the fountain. Livestock will tend to gather in this protected area, enticing them to drink more. Access panel should be opposite of prevailing winter wind to give additional protection to the supply line.
Page 3
H. Anchoring Fountain –The OmniFount 5 & 10 have 6 molded hold-down pockets. The use of 3/8” x 5” stainless steel expansion anchor bolts (not included) is recommended. Anchor bolts are available from Ritchie in a two pack, part #16555. Large diameter fender washers are included and should be used with anchor bolt to prevent damage to the plastic casing.
Page 4
I. Valve Assembly – The valve assembly can be put together before proceeding. 1. Install standpipe into hole in trough. Rubber washer is to be on inside of trough. Tighten nut hand tight to allow for adjustment after valve assembly is installed. 2.
Page 5
L. Electrical Connection - The electrical installation should be made and maintained by a qualified electrician conforming to national and local codes. A means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. For wiring connections, see wiring diagram. Make connections according to the wiring diagram below.
Page 6
Ritchie Valves Ritchie valves come in various sizes and pressure ratings as shown below - green for high supply line pressure, red for moderate supply pressure, and white for low-pressure applications. Differences in the size of trough also impacts valve choice.
Trouble Shooting Problem Solution Adjust thermostat to lower temperature Water in Trough Too Warm Check to see if thermostat has failed by contacts burning closed Check fuses or circuit breakers Check all heating elements to make sure they are working and hot Adjust thermostat to higher temperature Ice in Trough Check for voltage from thermostat output...
Page 8
WIRING DIAGRAM FOR HEATED UNITS 120V UNITS - SINGLE PHASE THERMOSTAT TROUGH HEATER CABLE (3) WIRE CONNECTORS FIELD SUPPLIED FENWAL OR DISC 120V HEATER 120V BLACK BLACK GREEN GROUND WHITE NEUTRAL BLACK HOT COMMERCIAL POWER WARNING - CHECK NAMEPLATE FOR CORRECT NOTE: Power cord may be supplied on select units to simplify VOLTAGE.
Ritchie Industries’ liability for any defects in material or workmanship with respect to accepted goods shall be limited to repairing the goods or replacing them as Ritchie Industries shall elect. Parts used in warranty repairs will be warranted for the balance of the water system’s warranty period, with all parts replaced under warranty becoming the property of Ritchie...
Page 13
This page intentionally left blank OmniFount Large Series Instruction Manual August 13, 2022...