Summary of Contents for Ritchie CattleMaster CM10T

  • Page 1 This unit is built to give you excellent service when properly installed and maintained. Please follow instructions carefully. Read and understand all instructions before installing Ritchie Industries, Inc. 800-747-0222 Part # 17873 January 1, 2020 www.ritchiefount.com...
  • Page 2: Installation Instructions

    16417 2’ Top Section or down to horizontal underground water line. For optimum water line protection, use the 12” diameter insulated Ritchie Thermal Tube, part numbers and sizes are shown 16612 4’ Top Section to the right. Tube opening must be kept clear.
  • Page 3 F. Preparing the Bottom - Apply the provided foam weather stripping to the bottom of the unit, along the outside edge of the fountain. G. Anchoring Fountain - CattleMaster Fountains have mounting pockets molded into the base. Use of Ritchie part #16555, stainless steel anchor bolts (not included), is recommended.
  • Page 4 K. Drain Plug – Insert the drain plug firmly into the drain hole in the trough. The plug can be tightened by tightening the eyebolt through the center of the plug. Water Seal Drain – Install the small drain plug into the drain hole in the water seal groove around the valve chamber seal.
  • Page 5 WIRING DIAGRAM 120V SINGLE PHASE WIRING DIAGRAM 240V SINGLE PHASE CattleMaster Series Instruction Manual January 1, 2020...
  • Page 6 N. Float Adjustment – Open water-supply shut-off valve, check for and fix any leaks. Adjust float for a water depth of 2 inches below top of trough or overflow pipe by adjusting the thumbscrew. With the valve functioning properly and the water level set at the proper level, you may install the valve cover. The water seal groove between the frame and valve cover must be filled with liquid to create a protective seal from cold winter air getting to the valve.
  • Page 7: Product Specifications

    Ritchie Valves Ritchie valves come in two sizes and three pressure ratings – green for high supply line pressure, red for moderate supply pressure, and white for low-pressure applications. Differences in the size of trough also impacts valve choice. Although different pressure rated valves may be used in a fountain, each fountain will only accommodate one size and configuration of valve.
  • Page 8 6. Remove the green screw (Item #5) holding the ground lug to the bracket and reattach on the opposite side of the bracket. Be sure to include the green wire under the screw. 7. Relocate the 3 Ritchie plug (Item #6) to the other end of the casing. Loosen wing nut to remove and tighten when reinserted.
  • Page 9 17679 CM Bulkhead fitting 2" 16534 Fenwal Thermostat SS pkg 1 pkg 17678 Drain Elbow Fitting 1 pkg 18849 Ritchie 2" Plug pkg 1 pkg 18320 O-Ring Fenwal (6/pkg) 18074 Nut Brass Fenwal (6/pkg) 1 pkg 18852 CM Drain Assembly pkg 1 pkg 18266 Frame Bolt &...
  • Page 10 17679 CM Bulkhead fitting 2" 16534 Fenwal Thermostat SS pkg 1 pkg 17678 Drain Elbow Fitting 1 pkg 18849 Ritchie 2" Plug pkg 1 pkg 18320 O-Ring Fenwal (6/pkg) 18074 Nut Brass Fenwal (6/pkg) 1 pkg 18852 CM Drain Assembly pkg 1 pkg 18266 Frame Bolt &...
  • Page 11 17679 CM Bulkhead fitting 2" 16534 Fenwal Thermostat SS pkg 1 pkg 17678 Drain Elbow Fitting 1 pkg 18849 Ritchie 2" Plug pkg 1 pkg 18320 O-Ring Fenwal (6/pkg) 18074 Nut Brass Fenwal (6/pkg) 1 pkg 18852 CM Drain Assembly pkg 1 pkg 18266 Frame Bolt &...
  • Page 12 17679 CM Bulkhead fitting 2" 16534 Fenwal Thermostat SS pkg 1 pkg 17678 Drain Elbow Fitting 1 pkg 18849 Ritchie 2" Plug pkg 1 pkg 18320 O-Ring Fenwal (6/pkg) 18074 Nut Brass Fenwal (6/pkg) 1 pkg 18852 CM Drain Assembly pkg 1 pkg 18266 Frame Bolt &...
  • Page 13: Troubleshooting

    Trouble Shooting Problem Solution Adjust thermostat to lower temperature Water in Trough Too Warm Check to see if thermostat has failed by contacts burning closed Check fuses or circuit breakers Check all heating elements to make sure they are working and hot Adjust thermostat to higher temperature Ice in Trough Check for voltage from thermostat output...
  • Page 14 E f f e c t i v e S e p t e m b e r 2 0 1 2 Poly Units Ritchie Industries, Inc. warrants its products to be free of defective materials and workmanship. Defective Base, top and ball...