Installation
▶ Tighten the union nut hand tight [4].
2
1
Fig. 16 Mounting the boiler siphon
With pump assembly
▶ Mount the tee [1] between the diaphragm safety valve and the
siphon.
▶ Connect the hose [2] from the automatic air vent valve to the tee [1].
▶ Do not insert the hose into the tee by more than 10 cm.
▶ Shorten the hose if required.
▶ Install the corrugated hose [3].
Without pump assembly
▶ Mount the corrugated hose [3] directly on the siphon [4].
▶ Connect the hose [2] from the automatic air vent valve to the waste
water system.
16
4.
3.
0010033908-003
4
1
3
Fig. 17 Mounting the air vent valve hose
[1]
T-piece
[2]
Air vent valve hose
[3]
Corrugated hose
[4]
Condensate trap
6.7

Connecting the condensate pipe

NOTICE
If the waste water pipe is blocked, this can damage the boiler.
A blockage in the waste water pipe can prevent the removal of
condensate from the boiler if the condensate drain line is permanently
connected to the waste water pipe.
▶ Make sure that the connection between the condensate pipes of the
boiler and the waste water pipe connection is unobstructed.
▶ Use a waste water pipe made of plastic material with a diameter of at
least Ø 40 mm to remove the condensate.
▶ Install a siphon in the waste water pipe.
▶ Install horizontal pipe sections so they slope towards the downpipe.
The maximum length of the horizontal pipe section in this case is 5 m.
▶ Fill siphon in the waste water pipe.
6.8
Connecting heating pipes (without connection set)
NOTICE
If the operating pressure is too high, this can damage the boiler.
▶ Install a diaphragm safety valve between the boiler and the service
shut-off valve.