Maintenance; Troubleshooting - Galvin Specialised Flowmatic Tubular 2030 Product Installation Manualline

Electronic soap dispenser wall mount
Table of Contents

Advertisement

NOTE: Do not mix used batteries with new ones.
Important: Spent batteries should not be disposed of with normal household waste.
Contact your local authority for information on waste disposal and recycling.

MAINTENANCE

Care and cleaning of chrome and special finishes
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. Use of any prohibited
cleaning or maintenance products or substances could damage the surface of the soap dispenser. For surface
cleaning use ONLY soap and water, then wipe dry with a clean cloth or towel. When cleaning bathroom tiles, the
soap dispenser should be protected from any splattering of harsh cleansers.
Disassembling the soap pipe from the pump.
The soap pipe can be disconnected from the soap pump by a simple slide & pull action. The sliding ring of the
quick connection fixation nipple on the pump should be pulled down. It releases the open end of the soap pipe
which can then be easily pulled out.
Clean the soap tank.
Clean out the tank prior to refill by flushing warm water through the hoses and pump until clean water is released
from the spout. TIP: Keeping a spare tank will enable this process to be completed in a speedy and hygienic
manner with minimal downtime

TROUBLESHOOTING

PROBLEM
Continuous
discharge from the
nozzle
CAUSE
SOLUTION
The connector should be inserted fully until
AUX
white O-ring is not visible. Remove the O-
connector not
ring if necessary
fully inserted
Version 1, 17 March 2021, Page 9 of 12
ILLUSTRATION

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tz-flowsoap1

Table of Contents