5. AC Voltage
Range
OL Reading
600.0mV
6.000V
60.00V
600.0V
1000V
LCD displays 0 counts when the reading < 10 counts.
Input Impedance:
Frequency Response: 45~500Hz(Sine Wave)
Overload Protection: AC/DC 1000V
6. Auto Voltage
Range
600.0V
1000V
LCD displays 0 counts when the reading < 10 counts.
Input Impedance :
Frequency Response : 45 ~ 500Hz (Sine Wave)
Overload Protection : AC/DC 1000V
7. DC Current
Range
6.000A
10.00A
Maximum measurement time :
>5A for max.3 minutes with at least 20 minutes rest time.
>10A for max.30 seconds with at least 10 minutes rest time.
Overload Protection : AC/DC 11A
Resolution
660.0mV
0.1mV
6.600V
0.001V
66.00V
660.0V
1100V
OL Reading
Resolution
660.0V
1100V
OL Reading
Resolution
6.600A
20.00A
15
Accuracy
±(1.0% + 5D)
0.01V
±(1.0% + 3D)
0.1V
1V
Accuracy
0.1V
±(2.0% + 3D)
1V
Accuracy
0.001A
±(1.0% + 3D)
0.01A