Feit Electric TR2X4G2/6WY/WH Important Safety Instructions And Installation Manual page 4

2 ft x 4 ft lay-in troffer
Table of Contents

Advertisement

Available languages

Available languages

Installation (Continued)
6a
Connection Using Regular switch
Using wago connectors, Connect the building wires to the
wires coming from the fixture. (Black to Line Voltage, White to
Neutral and Green to Ground).
Do this by inserting wires on wago connectors. Make sure
wires are properly inserted into the wago connectors.
NOTE:
Purple and Grey wires
only to be used for
0-10v dimming,
see below.
Live
White
Black
Neutral
6b
Connection Using 0-10V Dimmer
(not compatible with standard dimmers)
Using wago connectors, Connect the building wires to the wires
coming from the fixture. (Black to Line Voltage, White to Neutral,
Green to Ground, Purple Wire from fixture to Purple wire from
Dimmer switch, Gray wire from fixture to Gray wire from dimmer
switch). Do this by inserting wires on wago connectors. Make
sure wires are properly inserted into the wago connectors.
Live
White
Black
Neutral
0-10V Dimming wires
(Dimmer) Purple
(Fixture) Purple
Green
Ground
Green
Ground
(Dimmer) Gray
(Fixture) Gray
7
Place all wiring back into the panel wiring compartment and
re-install wire connection cover back into place..
8
Bend hanging-hooks by 90º, as show below.
9
Place the panel into the ceiling and use hanging-hooks to
stabilize the panel on T-Bar.
4
WWW.FEIT.COM
RETAIN THIS MANUAL FOR FUTURE USE

Advertisement

Table of Contents
loading

Table of Contents