Download Print this page

Pioneer WT009GLFI22HLD Service Manual page 34

Multi inverter air conditioner
Hide thumbs Also See for WT009GLFI22HLD:

Advertisement

3. If the unit can't operate, please replace outdoor PCB
11.3.11 Display EC
Reason:
The signal communication fault between power module and IPM module.
Solution: Please replace the outdoor PCB.
9.3.12
Display EP
Reason: The compressor top temperature high or the sensor fault.
Solution: Check and replace the sensor or add some gas.
9.3.13 Display PA
Reason: Two or three machine modes collide.
Solution: Check whether one machine run in cooling another machine run in heating or other model.
9.3.14
Display D3.
Reason: Water full (This only apply to cassette or duct type).
Solution: Check and let water drain.
11.13.15 Display CL
Cause:
Air filter duty, the unit operation Cumulative time 500 hours, the controller will confirmation the filter
dirty and display CL.
Solution: Clean the air filter then cut off the power and supply again.
Air Conditioner Service Manual
42

Advertisement

loading