Download Print this page

Pioneer WT009GLFI22HLD Service Manual page 21

Multi inverter air conditioner
Hide thumbs Also See for WT009GLFI22HLD:

Advertisement

. Installation manual
.1 Installation Details
Connecting pipe length
Model
9K
12K
18K
Outdoor unit
Pipe length is
1 5 meters Max.
In doo r uni t
Mode
9K
12K
18K
Connecting cables
The power cord should be selected according to the following specifications sheet.
Appliance Amps
Air Conditioner Service Manual
Liquid
1/4
1/4
1/4
Standard length: m
5.0
5.0
5.0
5
10
13
18
25
30
Pipe size(Inch)
Refrigerant piping
Max. length: m
15
15
15
Wire Size
AWG21/0.75 mm2
AWG18/1.0 mm2
AWG15 /1. 5 mm2
AWG14/1.6 mm2
AWG12/2.0 mm2
AWG10/2.5 mm2
Gas
3/8
3/8
1/2
Indoor unit
Pipe length i s
15 meters Max.
Outdoor unit
Additional refrigerant
Calculation: ×g=20g/m(A-5m)
15g/m
15g/m
20g/m
20