Download Print this page
Stanley IW1214001 User Manual

Stanley IW1214001 User Manual

Hydraulic impact wrench

Advertisement

Quick Links

Infrastructure
Safety, Operation & Maintenance
IW12 Hydraulic Impact Wrench
66023 User Manual 2/2022 Ver. 23
DECLARATION OF CONFORMITY
ÜBEREINSTIMMUNGS-ERKLARUNG
DECLARATION DE CONFORMITE CEE
DECLARACION DE CONFORMIDAD
DICHIARAZIONE DI CONFORMITA
______________________________________________________________________
I, the undersigned:
Ich, der Unterzeichnende:
Je soussigné:
El abajo firmante:
lo sottoscritto:
hereby declare that the equipment specified hereunder:
bestätige hiermit, daß erklaren Produkt genannten Werk oder Gerät:
déclare que l'équipement visé ci-dessous:
Por la presente declaro que el equipo se especifica a
Dichiaro che le apparecchiature specificate di seguito:
1.
Category:
Kategorie:
Catégorie:
Categoria:
Categoria:
2.
Make/Marke/Marque/Marca/Marca
3.
Type/Typ/Type/Tipo/Tipo:
4.
Serial number of equipment:
Seriennummer des Geräts:
Numéro de série de l'équipement:
Numero de serie del equipo:
Matricola dell´attrezzatura:
Has been manufactured in conformity with
Wurde hergestellt in Übereinstimmung mit
Est fabriqué conformément
Ha sido fabricado de acuerdo con
E' stata costruita in conformitá con
Directive/Standards
Richtlinie/Standards
Directives/Normes
Directriz/Los Normas
Direttiva/Norme
EN ISO
EN ISO
EN ISO
EN ISO
EN ISO
EN ISO
EN ISO
Machinery Directive
5.
Special Provisions:
Spezielle Bestimmungen:
Dispositions particulières:
Provisiones especiales:
Disposizioni speciali:
6.
Representative in the Union: Patrick Vervier, Stanley Dubuis 17-19, rue Jules Berthonneau-BP 3406 41034 Blois Cedex, France.
Vertreter in der Union/Représentant dans l'union/Representante en la Union/Rappresentante presso l'Unione
Done at/Ort/Fait à/Dado en/Fatto a STANLEY Infrastructure, Milwaukie, Oregon USA
Signature/Unterschrift/Signature/Firma/Firma
Position/Position/Fonction/Cargo/Posizione
Gunishetty, Shravan
Surname and First names/Familiennname und Vornamen/Nom et prénom/Nombre y apellido/Cognome e nome
continuación:
Hydraulic Hand-Held Impact Wrench
STANLEY
IW1214001, IW1234001, IW12140AX
All
No.
Approved body
Nr
Prüfung durch
Numéro
Organisme agréé
No
Aprobado
n.
Collaudato
12100:2010
Self
4413:2010
Self
28927-2:2009 +A1:2017
Self
3744:2010
Self
11148-6:2012, Cl. 5.4
Self
11148-6:2012, Cl. 5.5
Self
13732-1:2008
Self
2006/42/EC:2006
Self
None
North America Quality Engineer
Date/Datum/le/Fecha/Data
4-12-2021

Advertisement

loading
Need help?

Need help?

Do you have a question about the IW1214001 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Stanley IW1214001

  • Page 1 Provisiones especiales: Disposizioni speciali: Representative in the Union: Patrick Vervier, Stanley Dubuis 17-19, rue Jules Berthonneau-BP 3406 41034 Blois Cedex, France. Vertreter in der Union/Représentant dans l’union/Representante en la Union/Rappresentante presso l’Unione Done at/Ort/Fait à/Dado en/Fatto a STANLEY Infrastructure, Milwaukie, Oregon USA...
  • Page 2 2 | IW12 User Manual...
  • Page 3 10 11 12 9 10 11 IW12 User Manual | 3...
  • Page 4 IW12 Seal Kit (not shown) - * In seal kit 28788 “Read the Manual” Decal IW12 Trigger & Spool Assembly- Detail G ITEM DESCRIPTION 88348 “Read the Manual” Decal - Model IW1214001 00786 Cap Screw 88344 Importer Decal - Model IW1214001 07724 29087...
  • Page 5: Safety Precautions

    • Use only replacement parts recommended by STANLEY. • Do not force the tool to do the work of a larger tool. Use the correct Always observe safety symbols. They are included for your safety and for the tool for your application.
  • Page 6 Use and maintain as recommended in the manual to prevent an unnecessary increase in vibration. • Check the vibration level after each service. If higher than normal, contact your STANLEY dealer. Hydraulic • Warning: Hydraulic fluid under pressure could cause skin injection injury.
  • Page 7 Flow 4-12 GPM (15-45 LPM) Circuit Type “D” Decal Hydraulic Circuit Type Open Center CE Decal - Models IW1214001, Max. Relief Pressure 2100 PSI (145 BAR) IW12140AX & IW1234001 Recommended Back 250 PSI (17 BAR) - Can be used with higher...
  • Page 8: Tool Maintenance

    Note: Only use the sizes and types of accessories and consumables that are Torque the four cap screws that hold the impact mechanism to the tool recommended by STANLEY for threaded fasteners. Do not use other types or to 13-15 ft. lbs. (17-20 Nm).
  • Page 9: Troubleshooting

    See “Grease the Impact mechanism Impact Mechanism” on needs to be lubricated. page 8. Impact mechanism is Contact your STANLEY worn or damaged. dealer for service. Ensure the power source is delivering proper flow and pressure. See Hydraulic power source “Specifications”...
  • Page 12 STANLEY Infrastructure 6430 SE Lake Road, Portland, Oregon 97222 USA (503) 659-5660 / Fax (503) 652-1780 www.stanleyinfrastructure.com © 2014 Stanley Black&Decker, Inc. New Britain, CT 06053 USA...