Blower Installation - Empire Comfort Systems MILLIVOLT DVCP36SP30N-1 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for MILLIVOLT DVCP36SP30N-1:
Table of Contents

Advertisement

1.
Remove the glass and screen frames, and the bottom
access panel from the side which is opposite the valve.
The glass and screen frame may be removed as a unit. It is
not necessary to separate the screen frame from the glass
frame.
2.
Hold the blower assembly so that the magnets are on your
right side, and insert it into the fireplace through the opening
to the right of the junction box. See Figure 1.
3.
Attach the magnet-side of the blower assembly to the outer
wall of the fireplace, and center it inside the fireplace using
the two holes in the floor as a visual guide. See Figure 1.
4.
Set the rheostat control on the fireplace floor, with the
rheostat bracket situated as far to the right as possible. See
Figure 2.
Page 8

BLOWER INSTALLATION

Figure 1
Figure 2
5.
Snap the fan control disc into the forked prongs on the valve
bracket. See Figure 3.
6.
If more than one receptical is necessary in order to complete
the installation, unscrew the junction box from the locating
tabs so that it can be moved rearwards and plug the blower
cord into one of the two bottom recepticals. See Figures 4
and 5.
7.
Re-attach the junction box to the locating tabs.
8.
Re-install the glass and screen frames, and the access
panel.
Figure 3
Figure 4
Figure 5