Horizontal Termination - Empire Comfort Systems MILLIVOLT DVCP36SP30N-1 Installation Instructions And Owner's Manual

Direct vent zero clearance gas fireplace heater
Hide thumbs Also See for MILLIVOLT DVCP36SP30N-1:
Table of Contents

Advertisement

One Elbow
B
A
TO BOTTOM
OF UNIT
INITIAL
PIPE
LENGTH
24in
EXAMPLE C
36in
8ft
EXAMPLE B
20ft
NOTICE: Pipe straps must be used every 2 feet to secure
venting.
Two 45° Elbows
Installation requirements to replace the first 90° elbow with two
45° elbows:
EXAMPLE VENT RUNS
INITIAL PIPE
A (Vertical)
LENGTH
24in
36in
8ft
20ft
Page 28
VENTING FIREPLACE - TOP

HORIZONTAL TERMINATION

INSTALLED
VERTICALLY
EXAMPLE VENT RUNS
B
A
(Horizontal
(Vertical)
Maximum)
6ft
10ft, 4in
7ft
15ft
12ft
17ft, 8in
24ft
10ft
Figure 42
B (Horizontal
Maximum)
6ft
10ft, 4in
7ft
15ft
12ft
17ft, 8in
24ft
10ft
Figure 43
Two Elbows
NOTICE: Subtract 3 feet from the total horizontal measurement
for each 90° elbow installed horizontally. Subtract 1-1/2 feet from
the total horizontal measurement for each 45° elbow installed
horizontally.
B
EXAMPLE VENT RUNS
INITIAL PIPE
A (Vertical)
LENGTH
36in
48in
8ft
20ft
Three Elbows
A
TO BOTTOM
OF UNIT
B
EXAMPLE VENT RUNS
A (Vertical)
6ft
7ft
12ft
24ft
INSTALLED
HORIZONTALLY
A
TO BOTTOM
OF UNIT
B (Horizontal
Maximum)
6ft
7ft, 4in
7ft
12ft
12ft
14ft, 8in
24ft
7ft
Figure 44
INSTALLED
VERTICALLY
INSTALLED
VERTICALLY
B (Horizontal Maximum)
10ft, 4in
15ft
17ft, 8in
10ft
Figure 45
36092-10-0619
INSTALLED
VERTICALLY