Fujitsu GENERAL ASWG18JFCB Operating Manual page 26

Cool model room air conditioner wall mounted type
Table of Contents

Advertisement

OPERATION
To Stop Operation
Press the START/STOP button (Fig. 5 L).
The OPERATION Indicator Lamp (green) (Fig.3 5) will go out.
About AUTO CHANGEOVER Operation
● When AUTO CHANGEOVER operation fi rst selected, the fan will operate
AUTO:
at very low speed for about a few minutes, during which time the unit de-
tects the room conditions and selects the proper operating mode.
Room temperature is higher than the defi ne temperature in temperature
setting → Cooling mode or Dry mode
Room temperature is close to or lower than the defi ne temperature in tem-
perature setting → Monitor operation
● When the air conditioner has adjusted your room's temperature to near
the thermostat setting, it will begin monitor operation. In the Monitor op-
eration mode, the fan will operate at low speed. If the room temperature
subsequently changes, the air conditioner will once again select the ap-
propriate operation (Cooling) to adjust the temperature to the value set in
the thermostat.
● If the mode automatically selected by the unit is not what you wish, select
one of the mode operation (COOL, DRY, FAN).
About Mode Operation
Cooling: ● Use to cool your room.
● Use for gently cooling while dehumidifying your room.
Dry:
● You cannot heat the room during Dry mode.
● During Dry mode, the unit will operate at low speed; in order to adjust
room humidity, the indoor unit's fan may stop from time to time. Also, the
fan may operate at very low speed when adjusting room humidity.
● The fan speed cannot be changed manually when Dry mode has been
selected.
● Use to circulate the air throughout your room.
Fan:
En-7
Cooling mode
or Dry mode
Defi ned
temperature in
temperature
Monitor operation
setting
During Cooling/Dry mode:
Set the thermostat to a temperature setting
that is lower than the current room tem-
perature. The Cooling and Dry modes will
not operate if the thermostat is set higher
than the actual room temperature (in Cool-
ing mode, the fan alone will operate).
During Fan mode:
You can not use the unit to heat and cool
your room.