Ai Trouble Shooting - Pegasus W500 Series Instructions Manual

Hide thumbs Also See for W500 Series:
Table of Contents

Advertisement

CAUTION
CAUTION
  
Always turn off the power, unplug the machine and then well-qualified technicians should troubleshoot a problem.
  
In the case of the adjustment that is made with the power on, well-qualified technicians should carry out this adjustment
with great care because the machine could start unexpectedly.
  
If trouble occurs frequently, stop using the device and contact your local dealer or Pegasus' sales office.
Symptom
The Al device is not
turned on.
While the power of the
machine is on, the motor
for the Al device keeps
on running.

AI Trouble shooting

Cause
The power relay cord is not
connected correctly to the
controller.
Faulty wiring inside the power
switch (push button)
The fuse for the controller has
a break.
Three sensors on the Al motor
are out of where these sensors
can detect the lever.
When the power or the machine
is off, the differential lever is out
of any one of three sensors.
The relay cords for three sensors
on the Al motor are disconnected.
Remedy
Connect the power relay cord correctly.
At this time check to make sure the
power relay cord to be used matches
the supply voltage.
Connect the wires of the same colors.
Replace the fuse.
Position the lever as shown below.
In the case of the
In the case of the
maximum reverse
maximum differential
differential feed
feed
Even if the power or the machine
is off, the differential lever should
be aligned with any one of three
sensors.
Connect the relay cords of the
same colors correctly.
Reference
page
11
11
10
6
7
11