Step4-3
■ How to connect the waterproof RJ45 connector
Step4-4
■ 24 V AC power cable
A
Recommended wire
AWG size
#24
#22
(Twisted wire)
(0.22 mm
2
)
(0.33 mm
2
)
5 m
5 m
Wire length
{16.4 feet}
{16.4 feet}
B
Pin array of the connector housing (accessory)
Not use
24 V AC NEUTRAL (blue)
#20
#18
(0.52 mm
2
)
(0.83 mm
2
)
15 m
20 m
{49.2 feet}
{65.6 feet}
Ground (black)
24 V AC LIVE (brown)
C
Assembly of the 24 V AC connector kit (accessory)
Approx. 3 mm
{1/8 inches}
Cable
Upper
side
Insert Contact
A
(accessory)
Crimp
MOLEX manual crimping tool
57027-5000 (for UL1015)
57026-5000 (for UL1007)