Download Print this page

Product Specifications - Goodman GMEC96 Series Manual

Two-stage, multi-speed ecm gas furnace up to 96% afue
Hide thumbs Also See for GMEC96 Series:

Advertisement

Heating Data
High Fire Input¹
High Fire Output¹
Low-Fire Input¹
Low-Fire Output¹
AFUE²
Temp. Rise Range (°F)
Vent Diameter³
No. of Burners
Circulator Blower
Available AC @ 0.5" ESP
Size (D x W)
Horsepower @ 1075 RPM
Speed
Filter Size (in²) (Qty)
Electrical Data
Min. Circuit Ampacity⁴
Max. Overcurrent (amps)⁵
Shipping Weight (lbs)
¹
Natural Gas BTU/h
²
DOE AFUE based upon Isolated Combustion System (ICS)
³
Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace
input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require
larger wire sizes.
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
Gas Service Connection ½" FPT
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all
cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
SS-GMEC96
Downloaded from
ManualsNet.com
GMEC96
GMEC96
GMEC96
0303ANA
0403ANA
0603ANA
30,000
40,000
60,000
28,800
38,400
57,600
21,000
28,000
42,000
20,160
26,880
40,320
96
96
20 - 50
20 - 50
30 - 60
2" - 3"
2" - 3"
2" - 3"
2
2
1.5 - 2
1.5 - 3
1.5 - 3
11" x 6"
11" x 6"
11" x 6"
1/2
1/2
5
5
(1) 16 x 25
(1) 16 x 25
(1) 16 x 25
(side) or
(side) or
(side) or
(1) 14 x 25
(1) 14 x 25
(1) 14 x 25
(bottom)
(bottom)
(bottom)
8.6
8.6
8.6
15
15
106
106
110
search engine
GMEC96
GMEC96
GMEC96
0302BNA
0402BNA
0603BNB
30,000
40,000
60,000
28,800
38,400
57,600
21,000
28,000
42,000
20,160
26,880
40,320
96
96
96
20 - 50
20 - 50
35 - 65
2" - 3"
2" - 3"
2" - 3"
3
2
2
1.5 - 2
1.5 - 3
1.5 - 3
10" x 8"
10" x 8"
11" x 8"
1/2
1/2
1/2
5
5
5
(1) 16 x 25
(1) 16 x 25
(1) 16 x 25
(side or
(side or
(side or
bottom)
bottom)
bottom)
8
8
15
15
15
111
112
115
www.goodmanmfg.com

Product Specifications

GMEC96
GMEC96
GMEC96
0803BNA
0804CNA
1004CNA
80,000
80,000
100,000
76,800
76,800
96,000
56,000
56,000
70,000
53,760
53,760
67,200
96
96
96
35 - 65
25 - 55
35 - 65
2" - 3"
2" - 3"
2" - 3"
3
4
4
1.5 - 3
2.5 - 4
1.5 - 4
11" x 8"
11" x 10"
11" x 10"
1/2
1/2
3/4
5
5
5
(1) 16 x 25
(1) 16 x 25
(1) 16 x 25
(side or
(side or
(side or
bottom)
bottom)
bottom)
8
8
11.6
13.3
15
15
15
118
123
140
GMEC96
GMEC96
1005CNA
1205DNA
100,000
120,000
96,000
115,200
70,000
84,000
67,200
80,640
96
96
96
35 - 65
35 - 65
2" - 3"
2" - 3"
5
5
6
3 - 5
3 - 5
11" x 10"
11" x 11"
1
1
1
5
5
5
(1) 20 x 25
(1) 20 x 25
(bottom)
(bottom)
or (2) 16 x
or (2) 16 x
25 (side)
25 (side)
13.3
13.3
15
15
15
140
154
3

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Gmec96 0303anaGmec96 0403anaGmec96 0603anaGmec96 0302bnaGmec96 0402bnaGmec96 0603bnb ... Show all