MikroTik Cube 60G ac Manual
Hide thumbs Also See for Cube 60G ac:

Advertisement

Quick Links

Cube 60G ac
Cube 60G ac
(CubeG-5ac60ad)
It is the customer's responsibility to follow local country regulations, including operation within legal frequency channels, output power, cabling
requirements, and Dynamic Frequency Selection (DFS) requirements. All Mikrotik radio devices must be professionally installed.
Note. The information contained here is subject to change. Please visit the product page on
this document.

Safety Warnings

Before you work on any equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing
accidents.
Ultimate disposal of this product should be handled according to all national laws and regulations.
All installation methods for mounting an access point on any wall surface is subject to the acceptance of local jurisdiction.
The Installation of the equipment must comply with local and national electrical codes.
This product is intended to be mounted outdoors on a pole. Please read the mounting instructions carefully before beginning installation. Failure to use the
correct hardware and configuration or to follow the correct procedures could result in a hazardous situation for people and damage to the system.
Use only the power supply and accessories approved by the manufacturer, and which can be found in the original packaging of this product.
Read the installation instructions before connecting the system to the power source.
We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your
own risk!
In the case of device failure, please disconnect it from power. The fastest way to do so is by unplugging the power plug from the power outlet.
It is the customer's responsibility to follow local country regulations, including operation within legal frequency channels, output power, cabling
requirements, and Dynamic Frequency Selection (DFS) requirements. All Mikrotik radio devices must be professionally installed.
This is a class A device. In a domestic environment, this product might cause radio interference in which case the user might be required to take adequate
measures.

Quickstart

Connect the device to the included PoE injector with Ethernet cable;
Connect the PoE injector into the PC or to the network switch;
Connect the power adapter to the PoE injector;
Download WinBox configuration tool
Open WinBox and connect to the device;
Default IP: 192.168.88.1, user name:  admin  and there is no password;
Download the latest RouterOS software from
Choose ARM packages, and save them to your PC;
Open WinBox and upload downloaded packages, drag and drop into any windows;
Restart the device;
Connect again and select your Region in the Wireless menu, W60G tab, and in 
settings.
If the device RX blocking condition has happened device will restore its signal after a few seconds.

MikroTik mobile app

Use the MikroTik smartphone app to configure your router in the field, or to apply the most basic initial settings for your MikroTik home access point.
 https://mt.lv/winbox
;
 https://mikrotik.com/download
www.mikrotik.com
;
QuickSet 
menu set your Country, to apply country regulation
for the most up to date version of

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Cube 60G ac and is the answer not in the manual?

Questions and answers

Summary of Contents for MikroTik Cube 60G ac

  • Page 1 If the device RX blocking condition has happened device will restore its signal after a few seconds. MikroTik mobile app Use the MikroTik smartphone app to configure your router in the field, or to apply the most basic initial settings for your MikroTik home access point.
  • Page 2 Scan QR code and choose your preferred OS. Install and open the application. By default, the IP address and user name will be already entered. Click Connect to establish a connection to your device through a wireless network. Choose Quick setup and application will guide you through all basic configuration settings in a couple of easy steps. An advanced menu is available to fully configure all necessary settings.
  • Page 3 The IP rating scale for this device is IP54. When mounting outdoors, please ensure that any cable openings are directed downwards. We recommend using the POE injector and proper grounding with Cat6 shielded cable. When using and installing this device please pay attention to the Maximum Permissible Exposure (MPE) safety distance with a minimum of 20 cm between the radiator and your body.
  • Page 4 It's recommended to secure Ethernet cable to the pole using zip ties. With the distance from the device approximately 30 cm. As an additional option, you can use "quickMOUNT-X" – mounting bracket for an easy adjustment that can be obtained separately. Product web page: https ://mikrotik.com/product/qm_x Specially designed enables vertical and horizontal adjustment on the pole. Grounding The device includes a grounding connection (marked ) which you should connect to the grounding installation of the tower or building where the device will be used.
  • Page 5 Package includes the following accessories that come with the device: EU/US Switching Power Supply 24V DC , 0.8 A, 9 W, Level VI, cable:1.5 m. POE Injector with shielded ethernet cable/connector (RBPOE). Cube mount. K-70 Fastening set for Cube mount. Operating system support v6.47.2 The device supports RouterOS software version...
  • Page 6 Информация о дате изготовления устройства указана в конце серийного номера на его наклейке через дробь. Первая цифра означает номер года (последняя цифра года), две последующие означают номер недели. Изготовитель: Mikrotikls SIA, Aizkraukles iela 23, Riga, LV-1006, Латвия, support@mikrotik.com. Сделано в Китае, Латвии или Литве. Cм. на упаковке.
  • Page 7 País De Origen: Letonia; Lituania; China (Republica Popular); Estados Unidos De America; Mexico. Por favor contacte a su distribuidor local para preguntas regionales específicas. La lista de importadores se puede encontrar en nuestra página de inicio – https://mikrotik.com/buy/latinamerica/mexico. The National Commission for the State Regulation of Communications and Informatization by Ukraine Виробник: Mikrotikls SIA, Brivibas gatve 214i Рига, Латвія, LV1039.
  • Page 8 Betriebsfrequenz / maximale Ausgangsleistung Note. Information contained here is subject to change. Please visit the product page on   www.mikrotik.com   for the most up to date version of this Fréquence de fonctionnement / puissance de sortie maximale 5470-5725 MHz / 27 dBm document.

This manual is also suitable for:

Cubeg-5ac60ad

Table of Contents