This section describes the steps to take to upgrade the VEP4600's firmware if your VEP4600 arrived from Dell with the DiagOS as the
only operating system.
Topics:
•
Check the existing firmware version
•
Configure BMC Management Address in BIOS
•
Configure BMC Management address on BMC console
•
Run the Unified Firmware Updater from a Linux server
Check the existing firmware version
To check the current VEP4600 firmware versions when an Operating system is installed:
a. To find the CPLD and BIOS versions:
From the CPU mgmt console:
•
ESXi is installed: scroll up to last boot output to see BIOS and CPLD versions
•
DiagOS installed: login and type updatetool -D ALL -V
b. To find the BMC version:
From BMC mgmt console: type ipmitool -I lanplus -H 127.0.0.1 -U admin -P admin mc info
~ # ipmitool -I lanplus -H 127.0.0.1 -U admin -P admin mc info
Device ID
Device Revision
Firmware Revision
IPMI Version
Manufacturer ID
Manufacturer Name
Product ID
Product Name
Device Available
Provides Device SDRs
Configure BMC Management Address in BIOS
1. From the BMC console window, run the following commands to boot into the BIOS:
ipmitool -I lanplus -H 127.0.0.1 -U admin -P admin chassis bootparam set bootflag
force_bios
ipmitool -I lanplus -H 127.0.0.1 -U admin -P admin power reset
2. In the BIOS, tab to Server Mgmt menu, then move cursor down to BMC network configuration.
Select BMC network configuration
Upgrade Firmware through BMC
: 32
: 1
: 2.00
: 2.0
: 12290
: Unknown (0x3002)
: 1147 (0x047b)
: Unknown (0x47B)
: yes
: no
Upgrade Firmware through BMC
6
21