Change settings in the Barista menu

You have to leave the operational window of the controller and choose the correct parameter-set (in
the settings window) to change individual settings.
GROUP 1
operational window
STAND
menu window
FACTORY
settings window
BARISTA PASSWORD:
enter barista
password window
barista menu
window
SETTING

Sub-menu TEMP. SETTING

In the sub-menu temperature setting you can adjust the following:
parameter
temperature display
grp 1 temperature
80.0 .. 99.9°C
grp 2 temperature
grp 3 temperature
steam temperature
cup heater
show temp. at ECO
Note! Do not adjust the temperature of the hot water dispense by changing the temperature of the
steam-boiler. Change the mix-water temperature by turning the set screw on the inlet manifold.
4
The 3-digit display will go blank whenever a group is at ECO. This can be changed to keep showing
the temperatures but that will decrease the lifespan of the displays.
Slim Jim Idrocompresso User manual
Operation
GROUP 2
GROUP 3
93.4
45.6
EXTERNAL
BY
SENSOR
TECHNIC
BARISTA
LEVEL
LEVEL
use arrows to construct the password (10000)
TEMP.
WATER
TIMER
range
factory
°C, °F
°C
93.0°C
176 .. 212°F
199.4°F
110 .. 130°C
125°C
230 .. 266°F
257°F
0 .. 70 °C
70 °C
32 .. 158 °F
158 °F
4
no, yes
no
STEAM
93.2
124.6
13 : 57
CLEAN
SETTINGS
PROGRAM
MANAGER
LEVEL
LEVEL
touch
00000
TIMED
TIME
ON/OFF
DATE
increm.
unit
remark
0.1
In a Duette there is no group 3.
°C or °F
1
the cup-heater is OFF at "NO
1
HEAT" and "ECO-all"
When "yes" the digit displays will
show a temperature at ECO.
MENU
touch
touch
EXIT
use ˄˅ to change
ENTER
the value of the
underlined digit,
use ˂˃ to change
digit
touch
choose a sub-menu
EXIT
or exit to the
operational window
page 20