Installation of indoor unit
V. Installing decorative sheets
1. Verify with water level or water filled Polyethylene pipe that the indoor unit is horizontally
installed and specifications of the holes on the ceilings are correct. Remove the water level
before installing the decorative sheets.
2. Tighten the screws of the indoor unit ensuring that the height difference between the two
sides of the indoor unit is less than 5mm.
3. Apply two screws for preliminary fixing.
4. Apply the other and then tighten the four screws.
5. Connect the cable of the synchronous motor.
6. Connect the signal cables.
7. Verify that cable is correctly connected if the unit does not respond to remote controller
signals. Allow a 10-second lapse after disconnection of the power supply, and then restart
the remote controller.
Displaying
signals
Restrictions for top panel installation
1. Top panel is installed as shown in the figure.
2. Incorrect installation of the top panel may result in
air leaks and fluctuation, as well as failure of signal
transmission and display.
Water drainpipe
Faucet
Synchronous
motor
21
Pipe
Liquid intake
pipe
Backflow pipe
Water drainpipe