Introduction
Preparation
Following are necessary tools for installation:
1
.
Screw drivers (normal,
Philips-head and tricorn)
2
.
Hacksaw
.
3
60mm drill
.
4
Socket screw wrench
5
.
Adjustable spanner
Following materials are prepared by the owner:
Code
Material
Power supply requirements:
Voltage: single-phase1PH,220-230V**50Hz
Dedicated electrical cable(30A)should be installed by a qualified technician in accordance
with the state regulation for electrical engineering.
The power source must be grounded.
A circuit breaker must be installed
Electrical cables should be connected by ìYî method. Damaged or wornelectrical cable
must be replaced by authorized after sales agents.
The power plug should be connected as follows: L for live line, N for neutral line and
fo
grounding.
r
Connection parameters: H05RN-F*
Signal parameters:
Cables for power supply, connection and signals are prepared by the owner.
Specifications
Connection
Liquid pipe
duct dime-
nsions
Gas pipe
Tools for installation
6
7
8
9
A
B
C
2-sided
1-side adh-
Connection
adhesive
esive tape
hose
tape
3G(1.0-1.5)mm
2X(0.75-1.5) mm
H05RN-F*
Copper tube option
AB092FCBHA
O 6.35(1/4")
O 9.52(3/8")
*
*
.
Spanne
(14 17 19
24 and 27mm)
.
Pipe cutter
.
Expander
.
Knife
D
Water-proof
insulation
material
2
*
2
Shielded wire
AB142FCBHA
O 6.35(1/4")
O12.7(1/2")
15
*
10
.
Pliers
11
.
Leak tester and
soap solution
12
.
Steel tape
13
.
Scraper and file
14
.
Refrigeration
oil(polyol ester)
E
F
Drainage
Gesso
hose
*
AB182FCBHA
O 9.52(1/4")
O15.88(1/2")

Hide quick links: