MAINTENANCE AND ADJUSTMENTS
E. SEVERE CONDITIONS
The servicing intervals specifi ed are based on normal operating conditions. Operation
under severe or unusual conditions will require some adjustments in servicing intervals.
1. When the average temperature is above 80°F(26°C) or below -10°F(-23°C), reduce
service time intervals by one-half of those specifi ed above.
2. When operating in the presence of dust or sand, reduce service time intervals by one-
half of those specifi ed.
3. When operating in excess of twelve hours per day, reduce service time intervals by
one-half of those specifi ed.
4. When operating in air with high moisture or salt, the servicing intervals need not usually
be changed. However, the unit should be inspected weekly to determine if additional
servicing be required. Also, have hydraulic fl uid tested quarterly.
5. For extended inactive periods, the engine should be started at least once a week
and run until thoroughly warm. Servicing time intervals may be extended from those
specifi ed, but for actual time intervals, contact your local Caterpillar dealer, especially
during lengthy storage periods.
F. LUBRICATION
1. Crankcase (Diesel Engine)
a. Follow the engine manufacturer's maintenance schedule and the lubricating oil
specifi cations outlined in the CATERPILLAR OPERATION GUIDE.
b. The lubricant shall meet the performance requirements of API Service Classifi cations
CH-4.
c. New engines are shipped with Caterpillar SAE 15W-40 but the following multi-grade
crankcase oils are recommended for use or replacement in normal operation (10°F to
90°F) (-12°C to 32°C).