Further certificates, declarations of conformity and proof of performance can be found at The assembly instructions contain profile-independent information for the correct assembly of the www.maco.eu/instinct. INSTINCT by MACO system. These instructions include the work steps in the factory and the work steps on the construction site.
INSTINCT Guard / Guard+ INSTINCT striker plate INSTINCT Bluetooth module INSTINCT System cable INSTINCT System cable for frame-side assembly 6000 mm INSTINCT Gateway INSTINCT Termination cable (with or without acoustic module)* INSTINCT UPS Module INSTINCT power supply (DIN rail or flush-mounted)
Work steps in the door frame Work steps in the door frame 1. Milling checks 2. Connection of INSTINCT system cable and Bluetooth module Feed the INSTINCT system cable for frame-side assembly 6000 mm into the hole provided for this purpose.
Page 6
4. Connection of INSTINCT Guard / Guard+ Feed all system cables into the corresponding millings Connect all INSTINCT Guard / Guard+ (except the top / last according to the system folder. one) according to the following procedure and position them in the milled holes.
Page 7
Work steps in the door frame Work steps in the door frame 5. Connection of INSTINCT Guard / Guard+ and INSTINCT termination cable 6. INSTINCT Guard / Guard+ assembly Connect an INSTINCT system cable to the upper / last INSTINCT Guard / Guard+. On the second port, a termination PAY ATTENTION TO THE SYSTEM FOLDER cable must be connected.
65 and 66. ASSEMBLY NOTES Do not overtighten the screws to avoid twisting or deformation of the INSTINCT The assembly of the components is hereby striker plates. completed. On pages 29 and 38, the...
Work steps in the door leaf 1. Milling checks 2. Bluetooth module assembly – optional 1. When using an INSTINCT Bluetooth module, it must be placed and wired at the recommended positions (see system folder) before the INSTINCT Guard and Guard+ cabling.
Page 11
Work steps in the door leaf 3. INSTINCT cable transition assembly - sash side 4. Connection of INSTINCT interface and MACO openDoor access control – optional Insert the sash-side part of the cable transition When using the INSTINCT interface, it must...
Page 12
Work steps in the door leaf 5. Connection of INSTINCT Guard / Guard+ 6. Connection of INSTINCT GUARD / Guard+ and INSTINCT termination cable Connect all INSTINCT Guard / Guard+ (except Connect an INSTINCT system cable to the upper / the top / last one) according to the following last INSTINCT Guard / Guard+.
Page 13
Work steps in the door leaf Work steps in the door frame 7. INSTINCT Guard / Guard+ assembly 1. INSTINCT striker plate assembly PAY ATTENTION TO THE SYSTEM FOLDER PAY ATTENTION TO THE SYSTEM FOLDER Recommendations for suitable screws can...
Page 14
3. INSTINCT cable transition assembly Position and mount the frame-side part of the INSTINCT cable transition in the corresponding milling. Hang the sash in the frame. Connect both parts of the INSTINCT cable transition and then secure the connector with the enclosed screw.
2a. Locks in the frame - connect the INSTINCT system cable for frame-side assembly 6000 mm to the designated socket on the INSTINCT Test Kit. 2b. Locks in the sash - connect the end of the INSTINCT cable transition to the designated socket on the INSTINCT Test Kit.
Page 16
If noise occurs, the pin position can be adjusted manually. Please refer to the instructions on page 28. Manually operate the locking hooks of all INSTINCT Guard / Guard+ to check proper functionality. Thereafter, the hooks must be unlocked again immediately by the motor. Positioning Reference All locks are switched into normal operation after the door has been closed for the first time and lock automatically when the door is closed.
Page 17
Commissioning with Test Kit Check the contact pressure - for this the door can be unlocked via the INSTINCT Test Kit, the MACO Press the OPEN INT button on the INSTINCT Test Kit to unlock all locks at the same time.
Page 18
If the locks do not lock when the door 12. Disconnect the INSTINCT system cable (locks in the frame) or the INSTINCT cable transition (locks in the is closed, the day release is successfully sash) from the INSTINCT Test Kit.
Prepare delivery status Prepare delivery status Pack the door safely for transport. Since all locks are set to day release, the sash must also be secured Provisionally attach the connection cable to the door to avoid damage during transport. against uncontrolled opening during transport. The door is now ready for delivery.
Page 20
2a. Locks in the frame - connect the INSTINCT system cable for frame-side assembly 6000 mm to the corresponding socket on the INSTINCT Gateway. 2b. Locks in the sash - connect the end of the INSTINCT cable transition to the corresponding socket on the INSTINCT Gateway.
Page 21
Please refer to the instructions on page 28. Manually operate the locking hooks of all INSTINCT Guard / Guard+ to check proper functionality. Thereafter, the hooks must be unlocked again immediately by the motor. CONTROL SIGNAL - CLOSE...
3. Check contact pressure and, if necessary, adjust. 10. Disconnect the INSTINCT UPS from the INSTINCT Gateway for at least 3 seconds to reset the INSTINCT Gateway. Then, reconnect the UPS to the Gateway. TX 10...
Page 23
14. Activate the day release to prepare the door for delivery. For this purpose, the cable bridge must be clamped back onto pin 5 and 6. A detailed description of the PIN assignment for the INSTINCT Gateway can be found on page 48.
Prepare delivery status Prepare delivery status Pack the door safely for transport. Since all locks are set to day release, the sash must also be Provisionally attach the connection cable to the door to avoid damage during transport. secured against uncontrolled opening during transport. The door is now ready for delivery.
INPUT: Door opening from inside (Test Kit: OPEN INT) Function: Connection for external components to unlock the INSTINCT system Special features: Responds to parental control mode (opening the door requires 5-second, uninterrupted actuation) - Parental control is only available with INSTINCT Bluetooth module. Example: Opening switch...
Page 28
Remove the plug. INSTINCT Gateway. Shorten the cable. Feed the power supply line into the box for the INSTINCT power supply. Insulate the individual wires. Reconnect the wires according to the connector assignment (see table below). The use of connector sleeves is strongly recommended.
Page 29
Feed the cables from the INSTINCT UPS to the INSTINCT Power Supply and INSTINCT Gateway. 6b. Locks in the sash - feed the end of the INSTINCT cable transition into the wall up to the box for the Then, install the INSTINCT UPS in the designated box.
Page 30
10. Connect the INSTINCT UPS, the INSTINCT system cable / cable transition as well as all external components according to the connection diagram onto the INSTINCT Gateway and then install it in the...
Page 31
12. Connect the wall switch and install it in the designated box. 13. Insert the door leaf into the door frame and connect the ends of the INSTINCT cable transition to each other. The door remains open until the locks are commissioned.
Page 32
Commissioning Commissioning After the power supply has been established, the hooks of the INSTINCT Guard / Guard+ extend Test whether the locks respond properly to opening signals using the access control, INSTINCT App or automatically. switch. When functioning properly, a motorised noise can be heard from each lock and the lock hooks also move slightly.
Page 33
Commissioning Commissioning Close the door from the inside. The locks must run into the striker plates without any noise. Adjust the If noise occurs, the height of the pin can be adjusted manually. striker plate setting if necessary. 7-10 mm SW 7 CONTROL SIGNAL - CLOSE If an acoustic module...
Page 34
Check the contact pressure - for this purpose, the door can only be unlocked from the outside via the Attach the cover caps to the locks and the striker plates. access control or INSTINCT App. From the inside, the door can be opened by means of a wall switch. NOTES ON ADJUSTING THE CONTACT PRESSURE 1.
Page 35
Mayer & Co Beschläge GmbH MACO near you: Alpenstraße 173 · 5020 Salzburg · Austria www.maco.eu/contact T: +43 662 6196-0 · F: +43 662 6196-1449 maco@maco.eu · maco.eu This print document is constantly being revised. The current Created: 11 / 2021 · Changed: 13.05.2022 version can be found at http://www.maco.eu/assets/759439 Order No.