control sensor starts protection when the electronic temperature sensor gauge the
current temperature is higher than a certain value, to reduce the heating level of
the cooking zone cur rently, and resumes t he heating level afte r the temperature
drops.
light of the relative cooking zone will display, indic ating t hat cooking surface
temperature is too high, please do not touch to avoid getting burned.
time,the voltage between L/N of the plug should fall to below safe voltage range.
When a PCB board failure occurs, the timer di gital tubes on the display pa nel always
display the fault code, and all t
automatically return to the shutdown state after 1 minute. For th e burners that have
been worked, their indicator light continue to display slowly (display 1 time per
second) , indicating that cooking surface te mperature is too high . When the fault code
appears, please refer to the scheme in the following table to solve.
Fault code
All indicator lights
display quickly
(display
0.5s/times)
No.1,2,3 burners
indicator lights
display quickly
(display
0.5s/times)
No.2,3,4 burners
indicator lights
display quickly
(display
0.5s/times)
No.1,3 burners
indicator lights
display quickly
(display
0.5s/times)
No.2,4 burners
indicator lights
display quickly
(display
0.5s/times)
Put the pot in center of the heating zone, Turn the knob clockwise and anticlockwise to
turn on the hob.
When the whole applianc e stops heating, the i ndicator
For the models with plug,when cut off after 1S at any
he burners t hat are being heated stop heating, and
Type of fault
The display board does not
receive the signal of power
supply board.
The power supply board does
not receive the signal of
display board.
Power supply board relay
failure
1.Open circuit of the display
board NTC.
2.Short circuit of the display
board NTC.
High temperature protection
on the display board NTC.
Solution
The communication line failure
of power supply board or
display board can cause
communication anomalies.
Replace the display board
first. If the fault persists,
replace the power supply
board.
Replace the power supply
board.
Replace the display board
Replace the Insulated silicone
strip of circuit panel first. If
the fault persists, replace the
display board .