Factorydefault'command; Save'command - Sena NEMO10 User Manual

Table of Contents

Advertisement

- Exit and reboot the device
> help ip
set ip ipmode par1 par2 ...
- ipmode: static=Static IP / dhcp=DHCP / pppoe=PPPoE
- parameters:
if ipmode = static,
par1 = IP address,
par2 = subnet mask,
par3 = gateway
if ipmode = dhcp,
no parameters required
if ipmode = pppoe,
par1 = PPPoE username,
par2 = PPPoE password

2.4.4 ' factorydefault'Command

With ' factorydefault'command, users can load factory default parameter values in console. Command
usage of ' factorydefault'is as follows:
factorydefault [option] + <CR>
where,
- if option is omitted, all parameters are set with factory default values.
- if option='-ip', all parameters except IP settings are set with factory default values.
Loaded values are not saved until ' save'command invoked. After ' factorydefault" command, ' save'and
'reboot'commands are required for changes to take effect.
> factorydefault (or factorydefault –ip)
OK
> save
OK
> reboot

2.4.5 ' save'Command

With 'save'command, current parameter changes are saved to non-volatile memory. Command usage
of ' save'command is as follows:
Figure 2-18. Help screen
Figure 2-19. Help screen with ' ip'group specified
Figure 2-20. Factory default reset screen
24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nemo10-sk

Table of Contents