Command
set group par1 [par2 ...] + <CR>
get [group] + <CR>
help [group] + <CR>
factorydefault [option] + <CR>
save + <CR>
exit + <CR>
reboot + <CR>

2.4.1 ' set'Command

With ' set' command, users can configure parameter values of the NEMO10 for each environment.
Basic ' set'command usage is as follows:
set group par1 [par2 ...] + <CR>
where,
group = 'ip','host','serial' or 'admin'
par1 par2 ... = configuration parameters. Use * to keep a parameter's value
The ' group'is the category where the parameters should be entered. For example, if users want to set
parameters related to the IP configuration, use set command as shown in the Figure 2-12.
Table 2-4 NEMO10 command set summary
Description
Set configuration parameters
- group = 'ip', 'host', 'serial' or 'admin'
- par1 ... = configuration parameters. Use * to
keep a parameter's value
Get configuration parameter values
- group = 'ip', 'host', 'serial', 'admin' or 'status'
- If group is specified, shows settings of the
group.
- If group is omitted, shows settings of all groups.
Shows command usage screen.
- If group is omitted, shows help screen.
- If group is specified, shows 'set' command
usage of the group.
Restore factory default values
- if option is omitted, all parameters are set with
factory default values.
- if option='-ip', all parameters except IP settings
are set with factory default values.
Save changes
Exit without rebooting the device (changes are
not applied)
Exit and reboot the device
20
Result
If success,
"OK"+ <CR> + <LF>
If error
"ERROR" + <CR> + <LF>
Parameter value display
Help message display
If success,
"OK"+ <CR> + <LF>
If error
"ERROR" + <CR> + <LF>
If success,
"OK"+ <CR> + <LF>
If error
"ERROR" + <CR> + <LF>
If success,
"OK"+ <CR> + <LF>
If error
"ERROR" + <CR> + <LF>
None