Drolet HT-3000 Installation And Operation Manual page 39

Table of Contents

Advertisement

• The assembly should be as short and direct as possible between the stove and chimney. The use
of two 45o elbows is preferable to a single 90o elbow.
• The minimum overall height of the chimney system, measured from the stove top to the exterior
termination cap of the chimney should be at least 12' (3.66 m). A chimney which is too short may
lack the "tunnel effect" required to obtain a proper draft.
• Maximum number of 90o elbows: 2.
• Maximum unsupported horizontal length: 3' (1 m).
• Galvanized flue pipes must not be used because the coatings vaporize at high temperatures and
release dangerous gases. Use black painted flue pipes.
• Flue pipes must be at least 24 gauge in thickness.
• Flue pipe joints should overlap at least 1 ¼" (30 mm).
• Each joint in the assembly must be fastened with at least three screws.
• The installation must allow expansion: elbows in assemblies allow for expansion; straight assemblies
should include an inspection wrap with one end unfastened, or a telescopic section.
• Minimum upward slope towards the chimney: ¼ in/ft. (20 mm/m).
• One end of the assembly must be securely fastened to the flue collar with 3 sheet metal screws and
the other end securely fastened to the chimney.
• There must be provision for cleaning of the pipes, either through a clean out or by removal of the
pipe assembly. Removal of the assembly should not require that the stove be moved.
• The male ends of the sections must be oriented towards the appliance so that ashes and
condensation stay inside the pipe.
• A flue pipe must never pass through a combustible floor or ceiling or through an attic, roof space,
closet or concealed space. Where passage through a wall or partition of combustible construction
is desired, the installation shall conform to CAN/CSA-B365, Installation Code for Solid-Fuel-Burning
Appliances and Equipment.
• The chimney connector must be clean and in good condition.
Installation and Operation Manual - HT-3000
Page 39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Db07300

Table of Contents