Clearances - Drolet HT-3000 Installation And Operation Manual

Table of Contents

Advertisement

8.1

Clearances

APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
13 ¼" (337 mm)
A
B
14" (356 mm)
7 ¼" (184 mm)
C
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
13
WITH SINGLE WALL PIPE CONNECTOR
Canada
D
18" (457 mm)
24 ⅞" (632 mm)
E
F
18" (457 mm)
8.1.1
With Heat Shield AC02710 or AC02762
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
2 ½" (64 mm)
B
2 ½" (64 mm)
C
2 ½" (64 mm)
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
13
mentioned.
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
14
connector to be used as close as 6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.
Page 28
USA
13" (330 mm)
14" (356 mm)
7 ¼" (184 mm)
FROM PIPE CONNECTOR
USA
17 ¾" (451 mm)
24 ⅞" (632 mm)
18" (457 mm)
USA
2 ½" (64 mm)
2 ½" (64 mm)
2 ½" (64 mm)
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
6" (152 mm)
B
14" (356 mm)
C
7" (178 mm)
DISTANCES
FROM PIPE CONNECTOR
13
WITH DOUBLE WALL PIPE CONNECTOR
Canada
D
10 ¾" (273 mm)
24 ⅞" (632 mm)
E
F
17 ¾" (451 mm)
14
DISTANCES13 FROM DOUBLE WALL PIPE
CONNECTOR
Canada
D
7 ¼" (184 mm)
13 ⅜" (340 mm)
E
F
13 ¼" (337 mm)
Installation and Operation Manual - HT-3000
USA
6" (152 mm)
14" (356 mm)
7" (178 mm)
USA
10 ¾" (273 mm)
24 ⅞" (632 mm)
17 ¾" (451 mm)
USA
7 ¼" (184 mm)
13 ⅜" (340 mm)
13 ¼" (337 mm)