Exigence – static cold refrigeration unit on storage unit

Advertisement

i. Enter the Pr2 programming mode
To access settings present in "Pr2" (accessible to technicians), please contact
the secret code to access these settings.
4. Alarm signals
Message
"P1"
Atmospheric probe fault
"HA"
High temperature alarm
"LA"
Low temperature alarm
"EE"
Memory breakdown or fault
The alarm message is displayed until the alarm condition is re-established. All alarm messages are displayed
alternately with the atmospheric temperature except for "P1" which flashes. To reset the "EE" alarm and start
normal operation again, press on any key. The "rSt" message will be displayed for 3 seconds.
a. The EE alarm
The regulator includes an internal memory checking system. The "EE" alarm flashes when an internal memory fault
has been detected. In this case, the alarm output is activated.
b. Reestablishment of alarms
"P1" probe alarms (probe defect), "P2": they stop automatically 10 seconds after the probe has resumed normal
operation. Check the connections before putting back the probe.
"HA" and "LA" temperature alarms: they stop automatically when the regulator's temperature returns to normal
values or when defrosting starts.
5. Settings programmed in the factory
Setting
Set
Hy
AC
rES
IdF
MdF
ALU
ALL
ot
Adr
P2r
Vauconsant SA, all rights reserved A635xx -rev0-ENG, 22/10/2010
Cause
ON alarm output
Compressor output depending on "COn" and "COF" settings
ON alarm output
Other outputs unchanged
ON alarm output
Other outputs unchanged
ON alarm output
Other outputs unchanged
Name
Set point
Differential
Anti-short cycle time
Resolution
Interval between defrosting cycles
(Maximum) defrosting time
High temperature alarm
Minimum temperature alarm
Atmospheric probe calibration
Serial address (not used)
Access to the list of protected settings (read only)
USER MANUAL
, who will give you
Outputs
Value
-8
1
1
dE
7
0
8
2
0
1
- 11 -