ROUTE AND CONNECT HARNESSES

Left Side of the
Cabinet
1
For AP 113, and AP 123, first, using a Self-Tapping Screw
(VE7373K) or Cable Tie (VE4601K) and 4−Way Mount
(VE4650K) (see arrow), attach new harness to left side of
cabinet.
3
Next, using (4) cable ties and 4-way mounts, route the new main door harness behind last tray at the bottom.
Coin Box
AP 113, AP 123
INSTALLATION GUIDE
INSTALLATION GUIDE
AP 113, AP 123
4
6
Door Main Connector
Cabinet Main
Connector
CURVE™ Door AP 113, AP 123, AP 7000
CURVE™ Door AP 113, AP 123, AP 7000
Left Side of the
Cabinet
2
Ground Wire
Then, wind the green ground wire around main door harness
about 6 to 8 times. Next, secure main door harness to inside
of the cabinet (A) with Cable Clamp (VE4653K) and self-tap-
ping screw. Then connect ground to cabinet (B).
Then, for AP 113, and AP 123, run harness in front of machine
behind the coin box mounting
5
Next, disconnect cabinet's main harness from inside the top
of the machine (if necessary) so it has enough play to move
toward the bottom of the machine
Then, for AP 113, and AP 123, connect cabinet main
harness to the door main harness. The power for the coin
mech is no longer used.
A
B
(Continued next page)