Technical Data; Burner Equipment - Riello 40 G5 LC Installation, Use And Maintenance Instructions

Light oil burner type 445t1
Table of Contents

Advertisement

TECHNICAL DATA

TYPE
Thermal power – output
Fuel
Electrical supply
Motor
Capacitor
Ignition transformer
Pump
Absorbed electrical power
Burner with CE marking in conformity with EEC Directives: EMC 89/336/EEC - 2004/108/EC, Low
Voltage 73/23/EEC - 2006/95/EC, Machines 98/37/EEC and Efficiency 92/42/EEC.
The burner meets protection level of IP 40, EN 60529.
9
4
3
1 – Return line
2 – Suction line
3 – Gauge connection
4 – Pump pressure regulator
5 – Vacuum gauge connection
6 – Screws fixing air-damper
7 – Air damper
8 – Combustion head adjustment screw
9 – Lock-out lamp and reset button
10 – Flange with insulating gasket
445T1
28 – 60 kW
Light oil, viscosity 4 –6 mm
Single phase, 230 V ± 10%
Run current 0.75 A – 2850 rpm – 298 rad/s
4 F
Secondary 8 kV – 16 mA
Pressure 7 – 15 bar
0.130 kW
Fig. 1
7
6
6
10
D5400

BURNER EQUIPMENT

Quantity
2
1
4
1
1
1
1
GB
2.3 – 5 kg/h
2
/s at 20°C
~
50Hz
2
Description
Flexible oil pipes with nipples
Flange with insulating gasket
Screws and nuts for flange
to be fixed to boiler
Hinge
Screw and nuts for flange
Grommet
8
1
5
20013748

Advertisement

Table of Contents
loading

This manual is also suitable for:

200136282003513940 g

Table of Contents