Download Print this page

Optex OA-AXIS T Quick Start Manual page 2

Advertisement

Adjustments
1. Area depth angle adjustment
Depth angle
adjustment
screw
When adjusting the 1st row close to the door,
see Table 1 dipswitch 16 for the easier adjustment.
a. Independent adjustment
1st to 3rd rows
Depth angle adjustment screw for the 1st to 3rd rows.
Shallow
Deep
Red
Use the area adjustment tool (A) as shown above to
change the area depth angle for the 1st to 3rd rows.
4th and 5th rows
Depth angle adjustment screw for the 4th and 5th rows.
Shallow
Deep
Blue
Use the area adjustment tool (B) as shown above to
change the area depth angle for the 4th and 5th rows.
b. Simultaneous adjustment
For the simultaneous adjustment of the 1st to 5th rows, use the adjustment tool (C).
Reference
Area depth adjustment with INFRARED FINDER (Separately available)
1. Turn the depth angle adjustment screw to the right (Deep) to place the detection area most away from the door.
2. Set INFRARED FINDER sensitivity to "H" (High) and place it on the floor as shown below.
3. Turn the depth angle adjustment screw to the left (Shallow) until the emitting area is placed at the position where
INFRARED FINDER is in the low detection status. (Slow Red blinking)
Detection area
Detection area
2. Area width adjustment
1st to 3rd rows
4th and 5th rows
1 2 3
10 11 12
1 2 3
10 11 12
Eliminated
Eliminated
Eliminated
Eliminated
Narrow
Narrow
Wide
Wide
Width adjustment
Width adjustment
screws (Left)
screws (Right)
NOTE
When adjusting the width adjustment screws,
make sure to turn until it clicks otherwise the proper
operation may not be obtained.
1 2 3 cannot be eliminated separately, neither can 101112 .
3. Dipswitch settings
After changing the dipswitch settings, make sure to push the function switch for 2 s.
Table 1
Safety settings
Activation settings
Other settings
Dip
switch
Function
Setting
No.
Low
Middle
1
Sensitivity
1
2
1
2
2
2.0 to 2.2 m
2.0 to 2.5 m 2.5 to 3.0 m 2.5 to 3.0 m
*Floor condition
(*High refrection)
3
30 s
60 s
Presence timer
4
3
4
3
4
Setting1
Setting2
5
Frequency
6
5
6
5
6
N.C.
N.O.
Safety output
7
(to door controller)
7
7
OFF
ON
(High)
(Low)
Test input
8
(from door controller)
8
8
5 rows
4 rows
9
9
10
9
10
Row adjustment
10
OFF
ON
11
Immunity
11
11
N.O.
N.C.
12
Activation output
12
12
OFF
ON
Simultaneous
13
output
13
13
ON
OFF*
14
Self monitoring
14
14
Area adjustment tool
NOTE
B
Make sure that the detection area
A
does not overlap with the door/header,
and there is no highly reflecting object
near the detection area otherwise
C
ghosting/signal saturation may occur.
Deep
Shallow
2.0 (6'7")
3.0 (9'10")
2.0
1.0
0
-1.0
2.0
(6'7")
(3'3")
(3'3")
(6'7")
Deep
Shallow
2.0 (6'7")
3.0 (9'10")
3.0
2.0
1.0
0
3.0
(9'10")
(6'7")
(3'3")
(9'10")
INFRARED FINDER
Front view
0
2.0
(6'7")
1 2 3
4 5 6
7 8 9
3.0
(9'10")
2.0
1.0
0
(6'7")
(3'3")
Push 2 s
Factory default settings
Comment
Special attention to the setting is required
High
S-High
when the door is used often by the elderly or
children. Please adjust the sensitivity and the
1
2
1
2
presence detection timer according to your
risk assessment.
(*Low refrection)
The 1st and 2nd rows have the presence
2 s
detection function.
600 s
(Motion)*
To enable the presence detection, do not
enter the detection area for 10 s after setting
3
4
3
4
the timer.
Setting3
Setting4
When using more than one sensor close to
each other, set the frequency different for
each sensor.
5
6
5
6
Dipswitch 8
10 ms delay time between Test input and
Test input
Safety output.
Test
If the door controller has no Test, put Test
input to "OFF" and do not connect Black and
OFF
(High)
0 V
Red wires.
"High" or "Low" indicates the Test input signal
ON
level from door controller.
(Low)
0 V
Test
3 rows
2 rows
Set the depth rows with dipswitches 9 and 10.
9
10
9
10
When "2 rows" are selected, the Activation
output is disabled.
Set dipswitch 11 to "ON" when the sensor
operates by itself (Ghosting). When
dipswitch 11 is set to "ON" the actual
detection area may occur smaller.
Dipswitch12 is for the Activation output to
door controller.
When Dipswitch 13 is set to "ON", both
Activation & Safety output will operate
simultaneously regardless of detection area.
But only Safety output will respond back with
Safety output when it receives Test input.
When the door remains open and the operation
indicator shows Fast/Slow Green blinking, refer
to Troubleshooting. If the door still remains
open, set dipswitch 14 to "OFF".
Dip
switch
Function
No.
15
Direction
16
Installation mode
[m(feet,inch)]
* No EN 16005 compliance.
Service mode
- During the "Service mode", 1st row and 3rd to 5th row are transmitting. The operation indicator shows Yellow & Green blinking.
- After installation, be sure to turn to the "Operation mode" because it does not comply with EN 16005.
- The sensor automatically returns to "Operation mode" after 15 min from the transition.
1.0
0
-1.0
(3'3")
(3'3")
To Service mode
To Operation mode
[m(feet,inch)]
Checking
Check the operation in the operation mode according to the chart below.
Entry
2.0
1.0
0
(6'7")
(3'3")
Status
Operation indicator
12
Activation
output
12
7
Safety
output
*
7
* : During warm-up, Safety output is constantly active.
Inform building owner/operator of the following items
WARNING
1. Always keep the detection window clean. If dirty, wipe the window with a damp cloth.
Do not use any cleaner/solvent.
[m(feet,inch)]
2. Do not wash the sensor with water.
4
9
: Narrow
3. Do not disassemble, rebuild or repair the sensor yourself, otherwise an electric shock may occur.
1
12
: Wide
4. When the operation indicator blinks green, contact your installer or service engineer.
5. Always contact your installer or service engineer when changing the settings.
6. Do not paint the detection window.
NOTE
1. When turning the power ON, alwayswalk-test the detection area to ensure the proper operation.
2. Do not place any objects that move oremit light in the detection area. (e.g. plant, illumination, etc.)
10 11 12
Troubleshooting
1.0
2.0
(6'7")
(3'3")
Operation
Door operation
indicator
None
Door does not
open when a
person enters
Unstable
the detection
area.
Proper
Door opens
when no one
Unstable
is in the
detection area.
(Ghosting)
Proper
Proper
Yellow
Fast
Green
Blinking
Door remains
open
Slow
Green
Blinking
Red &
Green
Blinking
Slow
Green
Blinking
Proper
operation
Yellow &
Green
blinking
* After changing the dipswitch settings, make sure to push the function switch for 2 s.
Manufacturer
OPTEX CO., LTD.
5-8-12 Ogoto Otsu 520-0101, Japan
Tel : +81(0)77 579 8700
www.optex.net
Setting
Bi
Uni
15
15
OFF
ON
16
16
Keep pushing function switch for 5 s until the operation indicator starts to blink after off.
Keep pushing function switch until the operation indicator goes off.
Power
Outside of
OFF
detection area
-
Stand-by
None
Green
N.O.
OFF
N.C.
13
N.O.
N.C.
N.C.
OFF
N.O.
13
N.C.
ON
N.O.
Possible cause
Wrong power supply voltage.
Set to the stated voltage.
Wrong wiring or connection failure.
Check the wires and connector.
Wrong detection area positioning.
Check ADJUSTMENTS 1, 2, 3. (*)
Sensitivity is too low.
Set the sensitivity higher. (*)
Short presence timer.
Set the presence timer longer. (*)
Wipe the detection window with a damp cloth.
Dirty detection window.
Do not use any cleaner or solvent.
Wrong wiring or connection failure.
Check the wires and connector.
Objects that move or emit light in the
Remove the objects.
detection area.
The detection area overlaps with that
Check Table 1 dipswtich 5, 6. (*)
of another sensor.
Use the rain-cover. (Separately available)
Or wipe the detection window with a damp cloth.
Waterdrops on the detection window.
Do not use any cleaner or solvent.
Or install in a place keeping the waterdrops off.
The detection area overlaps with the
Adjust the detection area to "Deep" (Outside).
door/header.
Sensitivity is too high.
Set the sensitivity lower. (*)
Others
Set dipswitch 11 to "ON". (*)
Check Table 1 dipswtich 7, 8, 12. (*)
Wrong setting of dipswitches.
Check Table 1 dipswtich 1 to 4. (*)
Sudden change in the detection area.
If the problem still persists, hard-reset the sensor.
(Turn the power OFF and ON again.)
Wrong wiring or connection failure.
Check the wires and connector.
Installation mode is set to "ON".
Set dipswitch 16 to "OFF".(*)
Sensitivity is too low.
Set the sensitivity higher.(*)
Wipe the detection window with a damp cloth.
Dirty detection window.
Do not use any cleaner or solvent.
Sensitivity too low or sensor failure.
Contact your installer or service engineer.
Remove highly reflecting objects from the
Signal saturation. (1st or 2nd row)
detection area. Or lower the sensitivity. (*)
Or change the area depth angle for 1st to 3rd rows.
The detection area overlaps with the
Adjust the detection area to "Deep" (Outside).
door/header.
After changing the dipswitch settings, make sure
Setting error.
to push the function switch for 2 s.
Remove highly reflecting objects from the detection
Signal saturation. (3rd, 4th or 5th row)
area. Or lower the sensitivity. (*)
Or change the area depth angle.
Switch to the Operation mode that keep pushing
Service mode is enabled.
function switch until the operation indicator goes
off.
EMEA Subsidiary
OPTEX Technologies B.V.
Henricuskade 17, 2497 NB The Hague, The Netherlands
Tel : +31(0)70 419 41 00
info@optex.eu
www.optex.eu
Comment
When dipswitch 15 is set to "Uni", this setting
enables the door to close faster when a
person walks away from the door.
Uni-directional function is disabled in case the
detection at 1st and/or 2nd row  continues
for more than 5 s.
Set dipswitch 16 to "ON" to adjust the 1st row.
During the Installation mode only the 1st row
remains active and the operation indicator
shows yellow.
After setting the row set dipswitch 16 "OFF".
Entry into
Entry into
Entry into
3rd to 5th row
2nd row
1st row
Motion
Motion/Presence
detection
detection
Orange
Red
Red blinking
Possible countermeasures

Advertisement

loading