BURNER MANAGEMENT:
The burner is activated only when the machine is ARMED, this can only happen by activating the "ARM"
input
ARMING the appliance (ARM), the heating resistance will be activated (the "HEAT" light will come
on).
The heating will be deactivated only after reaching 100% of the operating temperature (the "HEAT"
light will flash).
When the temperature drops below the preset limit, it will reactivate for a few seconds.
See the description of the "HEAT" light shown above.
SHOT MANAGEMENT:
The shot is inhibited when:
- the appliance is disarmed
- It is in the "forced pause cycle" state (5 min.) after a shot
- the temperature of the burner is lower than that required to deliver dry, quality fog.
Fog delivery can be interrupted DISARMING the appliance or, if "T" Jumper is open, interrupting the signal
on the FOG terminal.
BACKUP BATTERY MANAGEMENT:
The backup battery must be connected before the appliance is switched on.
His state of health or presence is measured every 10 hours.
If the charge level is low (showing poor performance) the "BATT" LED will flash once per second.
Instead, in the case of a completely discharged or absent battery the "BATT" LED will emit a sequence of 3
flashes followed by a pause.
In both cases the "BAT" and "FAULT" outputs will be activated.
Once the battery has been replaced to reset the fault, the device must be restarted by disconnecting it or
by temporarily removing the fuse.