Wall or Ceiling Fixing
Make sure that the wall or ceiling chosen for the placement of the machine is suitable to
support the weight indicated in the technical data sheet.
Position the bracket as shown in the photo at a minimum distance of 15 cm from the ceiling.
Use 2 dowels (Fischer) of 10 mm of the type suitable for the wall where the machine will be installed.
IT IS POSSIBLE TO ROTATE THE APPLIANCE
For wall installation
PROVIDED THE ELECTRONIC PART AND THE
TANK ARE ALWAYS UNDER THE BURNER
In case of ceiling installation it is NECESSARY to equip the appliance with the
DT-SP2 accessory.
In the case of "Floating" installation (spaced from the ceiling), use 10 mm galvanized steel threaded rods
instead of the dowel screws and lock the bracket between nut and locknut.
~ 7 ~