Summary of Contents for DEFENDERTECH DT-800Lan

  • Page 1 Manual of installation and maintenance Fog Generators DEFENDERTECH DT-800...
  • Page 3 Warnings This appliance must only be used for the purpose for which it was expressly designed, any other use is to be considered improper and therefore dangerous. The current legislation does not allow the use of the device as an anti-theft device. The appliance is not intended for use by children under 18 or persons without the necessary technical skills.
  • Page 4 Warranty and Liability Conditions 1) With this warranty, TEK GROUP S.r.l., based in 61025 Montelabbate (PU), Via Leonardo Da Vinci n. 8, guarantees the product from any defects in materials and manpowers, provided that the use complies with the conditions indicated in the manual, for the duration of 24 months from the date of purchase of the product resulting from a fiscally valid document.
  • Page 5 Caution !!! Obligation to display The legislation provides for the obligation to post in the access route of the premises, a notice that signals the presence of a Fog Generator. Use the adhesive label supplied with the appliance.
  • Page 6 DEFENDERTECH® FOG GENERATOR DATA SHEET ETHERNET VERSION WITHOUT INTEGRATED ALARM CONTROL UNIT FEATURES AND PERFORMANCE DT-800Lan Fog dispensed in 60” 830 m3 effective continuous Fog dispsensing time 1-120 sec Forced breack time From 5 a 20 min Total dispensing time 6.5 min (with a full tank)
  • Page 7: Support Bracket Installation

    SUPPORT BRACKET INSTALLATION Make sure that the wall or ceiling chosen for the placement of the machine is suitable to support the weight indicated in the technical data sheet. Position the bracket as shown in the photo at a minimum distance of 15 cm from the ceiling. DO NOT TURN THE APPLIANCE For wall installation Use 4 10 mm dowels (fisher) of the type suitable for the wall on which the machine will be installed.
  • Page 8 PLACING THE MACHINE ON A SLED BRACKET 1. Take the appliance in the two points shown in the picture. Place the appliance on the front of the bracket and let the four fins of the bracket penetrate the side slits of the appliance (operation 1 °) 3.
  • Page 9 Description DT-800Lan Control Card...
  • Page 10 LEVEL (Liquid Level) "Clean" contact NC H24 (normally closed) when the DEFENDERTECH liquid level is acceptable. It will open when the level is in "reserve" (at least 60 "of autonomy available). It is recommended to bring the contacts to the control panel and create an unarmed area for signaling purposes.
  • Page 11 The common terminal of negative polarity, in common with "-12V", is to be used for the interaction with the terminals ARM, FOG and FOG2. ARM (N.A. by default but modifiable N.C) Bringing to this input the continuous signal taken from the terminal COM or -12v, it will emit a "beep" of 3 seconds, followed by the "armament"...
  • Page 12 FOG2 (N.A. by default but modifiable N.C.) This input, as for factory programming, behaves like the "FOG" input (in OR), through the "menu 2" of the special functions it is possible to modify the operating logic. "And-Fog2" Function By activating this function, the shot will be executed ONLY if FOG and FOG2 will receive an input in a 15- minute time window and the waiting period will be scanned with a beep per second.
  • Page 13 "BASE" DIP-SWITCH PROGRAMMING FUNCTIONING DIP1 DIP2 DIP3 DIP4 DIP5 DIP6 DIP7 DIP8 DIP9 DIP10 15 SEC 30 SEC 45 SEC 60 SEC NORMALLY OPEN (N.O.) NORMALLY CLOSE (N.C.) LIQUID RESET RESET BLOCK FOR FAILURE 5 MIN 10 MIN 15 MIN 20 MIN CONTINUE IMPULSIVE (DOUBLE THE...
  • Page 14 SPECIAL FUNCTIONS - MENU 1 It is possible to activate special functions that vary the operation of the two relay outputs and other functions such as: the deactivation of network failure signal on the relay, deactivate the liquid control, activate a relay during firing, deactivation of the burner washing cycle, "Bistable"...
  • Page 15 CAUTION!!! EVERY TIME YOU ENTER IN THIS MENU, THE SPECIAL FUNCTIONS ARE RESTORED TO THE FACTORY VALUES, so if for example we have used 2 special functions and we have changed our mind on one of these, entering in the menu again we will only need to reactivate the function that we intend keep (the other one will be deactivated automatically).
  • Page 16 FUNCTIONING A FAILURE STATE SIGNALING VIA LED ARMED APPLIANCE FIXED ON SLOW FLASHING DISARMED APPLIANCE ARMED LED1 DISARMED APPLIANCE BUT WITH ACTIVE BURNER FAST FLASHING PREHEATING FUNCTION (50% of maintenance) TURNED OFF ALL THE RESISTANCES OFF HEATING FIXED ON ALL THE RESISTANCES SELECTED ON LED2 ONLY ONE RESISTANCE ON;...
  • Page 17  At any time the firing phase can be interrupted, DISARMING the appliance; however, also in this case, the wash cycle will still be executed. ETHERNET NETWORK CONNECTIVITY: The DT-x00Lan series devices have been designed to be monitored and programmed remotely using the DEFENDERTECH "DT-FogControl" and "DT-MultiFogControl" software.
  • Page 18 Generators (even in different geographical sites). Both software can be requested free of charge by making a request (complete with social data) at the following address info@defendertech.eu IP ADDRESS AND PASSWORD RESET PROCEDURE 1. Disconnect ARM and FOG 2. Switch the appliance off completely 3.
  • Page 19 This signal does not affect the operation of the pumps, the machine will perform the firing procedure regardless. Reset the error by operating DipSwitch 5, if it persists contact the DefenderTech service. Check if there is liquid in the tank, otherwise the hose, the pump or the solenoid valve are faulty, contact the Service DefenderTech to be adviced on the action to be taken.
  • Page 20: Start-Up And Testing

    START-UP AND TESTING It is possible to test the machine independently from a connection to an alarm center. It is possible to freely test the system using "drinking water" instead of the liquid with which the fog is produced, from the appliance will come out a dry and transparent but "noisy" steam (at the end of this operation remember to restore the liquid level to the 100% acting on DipSwitch nr.4).
  • Page 21: Maintenance

    • Perform a full 60-second shot using water (repeat the operation if the steam generated emits a burnt smell) • Replace or top up the DEFENDERTECH liquid tank • Act on DIPSWITCH no. 4 to restore the liquid level to 100%...
  • Page 22: Declaration Of Conformity

    The manufacturer following tests carried out by the "EMCTEST-TECNOLOGIES" laboratory, declares under his responsibility that the devices: Items Denomination DT400plus/Lan/401 “DefenderTech Fog Generator” Device DT800plus/Lan/801 Fog Genrator for safety applications DT 1600plus/Lan/1601 They comply with the European Community Directives (Low Voltage), 2004/108/CE (Electromagnetic Compatibily), 2002/95/CE (RoHS) e 2002/96/CE (RAEE).
  • Page 23 via L. Da Vinci,8 61025 Montelabate (PU) Tel. 0721.1626113 Fax. 0721.0731145 info@TekGroupsrl.it E-mail: Partita IVA/Codice fiscale: 02503990414 Iscr. Reg. Impr. di Pesaro N°186978 SAFETY TECHNICAL SHEET DT-HEAVY FOG FLUID • CHEMICAL CHARACTERISTIC Liquid composed of Trimethylene glycol - 1,3 Propanediol used in the alimentation and preparation of pharmacological syrups. Easily miscible with water.