General Instructions
02-BRAM0806-V3-PEFC
8x6 Bramble Playhouse
BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY
- Check the pack and make sure you have all the parts listed.
- When you are ready to start, make sure you have the right tools at hand (not supplied)
including a Phillips screwdriver, Stanley knife, wood saw, step ladder and drill with 2mm
bit.
- Ensure there is plenty of space and a clean dry area for assembly.
TIMBER
As with all natural materials, timber can be a ected during various weather conditions.
For the duration of heavy or extended periods of rain, swelling of the wood panels may
occur. Warping of the wood may also occur during excessive dry spells due to an interior
moisture loss. Unfortunately, these processes cannot be avoided but can be helped. It is
suggested that the outdoor building is sprayed with water during extended periods of
warm sunshine and sheltered as much as possible during rain or snow.
Our buildings are pre treated with a water based treatment**; this only helps to protect
the product during transit and for upto 3 months against mould. To validate your
guarantee and ensure longevity of the product, it is ESSENTIAL the building is treated
with a wood preserver within the rst three months of assembly and thereafter in
accordance with the manufactures recommendations. Care must be taken to ensure
the product is placed on a suitable base.
BUILDING A BASE
When thinking about where the building and base is going to be constructed:
Ensure that there will be access to all sides for maintenance work and annual
treatment.
Ensure the base is level and is built on rm ground, to prevent distortion. Refer to
diagrams for the base dimensions, The base should be slightly smaller than the external
measurement of the building, i.e. The cladding should overlap the base, creating a run
o for water. It is also recommended that the oor be at least 25mm above the
surrounding ground level to avoid ooding.
TYPES OF BASE
- Concrete 75mm laid on top of 75mm hard-core.
- Slabs laid on 50mm of sharp sand.
Whilst all products manufactured are made to the highest standards of Safety and in
the case of childrens products independently tested to EN71 level, we cannot accept
responsibility for your safety whilst erecting or using this product.
Refer to the instructions pages for you speci c product code
WARNING: Only for domestic use
Not suitable for children under 36 month
To be used under direct supervision of an adult
Please retain product label and instructions for future reference
x2
All building's should be
erected by two adults
For ease of assembly, you
MUST pilot drill all screw
holes and ensure all screw
heads are countersunk.
2mm Drill bit
For ease of assembly, you
will need a tape measure to
check dimensions of
components.
**Protim Aquatan T5 (621)**
Your building has been treated with Aquatan.
Aquatan is a water-based concentrate which is diluted with water, the building as been treated by the correct
application of Aquatan solution and then allowed to dry.
Aquatan is a decorative nish to colour the wood, which is applied industrially to timber fence panels and
garden buildings.
Aquatan undiluted contains: boric acid, sodium hydroxide 32% solution, aqueos mixture of sodium dioctyl
sulphosuccinat and alcohols: 2, 4, 6-trichlorophenol.
For assistance please contact customer care on: 01636 880514
Mercia Garden Products Limited,
Sutton On Trent,
Newark,
Nottinghamshire,
NG23 6QN
www.merciagardenproducts.co.uk
Winter = High Moisture = Expansion
Summer = Low Moisture = Contraction
CAUTION
Every e ort has been made during the
manufacturing process to eliminate the
prospect of splinters on rough surfaces of the
timber. You are strongly advised to wear gloves
when working with or handling rough sawn
timber.
P 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 02-BRAM0806-V3-PEFC and is the answer not in the manual?

Questions and answers

Summary of Contents for Mercia Garden Products 02-BRAM0806-V3-PEFC

  • Page 1 For assistance please contact customer care on: 01636 880514 - Concrete 75mm laid on top of 75mm hard-core. - Slabs laid on 50mm of sharp sand. Mercia Garden Products Limited, Sutton On Trent, Whilst all products manufactured are made to the highest standards of Safety and in...
  • Page 2 02-BRAM0806-V3-PEFC Please retain product label and instructions for future reference Overall Dimensions: Width = 2663mm Depth = 2236mm Height = 2460mm Base Dimensions: Width = 2350mm Depth = 1753mm Before assembly please make sure you have a suitable base ready to erect your...
  • Page 3 Please retain product label and instructions for future reference Nail Bag Step 2 PI-02-0352 Place the Floor panel (No. 1) onto a rm 70mm Screw x 10 and level base, ensuring the base has suitable drainage & is free from areas 50mm Screw x 34 where standing water can collect.
  • Page 4 Please retain product label and instructions for future reference Step 4 Step 6 Assembly of the Door Panel (No. 2) and Fix the back of the Door Panel (No. 2) against Door (No.8). the sides of the Tall and Short Window Panels (No.
  • Page 5 Please retain product label and instructions for future reference Step 8 Step 10 Fix the Safety Rail (No. 9) suh to the side To make the Safety Rail secure, x the Railing of the Bunk Floor (No .6). Upright (No. 17) into place so that it is ush with the side of the the Bunk Floor and ush with Fix into position using 6x50mm screws as the Roof Bearer.
  • Page 6 Please retain product label and instructions for future reference Please retain product label and instructions for future reference Step 14 Step 12 Fix the Fascia Blocks (No. 16) to the Roof Place your ladder into postion and x using OSB (No. 7) using 3x30mm screws per block. 4x40mm screws.
  • Page 7 Please retain product label and instructions for future reference Step 16 Step 17 Roll the Felt (No. 31) from front to back leaving Fix the Fascias (No. 14 & No.15) using a 50mm felt overlap to the front, back and 3x40mm screws per board.
  • Page 8: After Treatment

    Please retain product label and instructions for future reference Step 19 Fix the Window Shutters(No. 12) and Window Box(No. 11) in position screwing from inside through the cladding as shown. 12x 30mm screws. 30mm Pre drill It is ESSENTIAL that you apply wood screw hole treatment immediately after the building...