INSTALLATION
Installation
10.2 Anti-scalding protection / temperature limit
WARNING Burns
When operating with preheated water, the set anti-scald-
ing protection may be ineffective.
f In this case, restrict the temperature at the upstream
f
central thermostatic valve (see chapter "Installation /
Appliance description / Accessories").
DCE 11/13
The anti-scalding protection "max. 43 °C" is activated by moving
the plug on the circuit board in the appliance cap.
60 °C
1
1 Anti-scalding protection not set
2 With anti-scalding protection 43 °C
f Remove the electronic PCB from the programming unit on
f
the appliance cover. Be careful with the snap-on hooks.
f Set the plug to the "43 °C" position.
f
f Refit the electronic PCB, ensuring the snap-on hooks click
f
into place. Observe the positions of the push-button and
shaft.
DCE 11/13 RC
The anti-scalding protection "max. 43 °C" is activated by changing
the setting of the DIP switch in the appliance.
4
1 DIP switch for anti-scalding protection
2 Without anti-scalding protection = 60 °C
3 With anti-scalding protection = max. 43 °C
4 Green LED indicator permanently illuminated when an-
ti-scalding protection is active
26
|DCE 11/13
43 °C
1
60°C
43°C

10.3 Installation options

Conversion for power connection from below
1
2
5
1 Connecting cable
2 Cable grommet
3 Strain relief
4 Mains terminal
5 Marking for hole
6 Plug
7 Wire guide
f Remove the strain relief, the power cable and the cable
f
2
grommet.
f Seal the top opening in the back panel using the enclosed
f
(sealed) plug. Protection rating IP 24 (splashproof) can only
be guaranteed with a correctly fitted plug.
f Reposition the mains terminal in the appliance from the top
f
to the bottom. Ensure that the mains terminal clicks into
place.
f Brake out the opening for the power cable. For this, use a
f
suitable tool to push the plastic in the circular marking out-
ward (working from the inside of the back panel). If neces-
sary, use a file.
Material losses
!
f If the appliance back panel is damaged, replace it.
f
2
f Fit the cable grommet in the new back panel.
f
f Route the power cable through the cable grommet in the
f
appliance back panel. Connect the power cable to the mains
terminal (see chapter "Installation / Specification / Wiring
diagram").
f Lay the control wires under the wire guide.
f
f Fit the strain relief.
f
3