Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the knob.
4. With a thin screwdriver, adjust the bypass
screw position (A).
A
5. If you change:
• from natural gas G20 20 mbar to liquid
gas, fully tighten the bypass screw in.
• from liquid gas to natural gas G20 20
mbar, undo the bypass screw
approximately 1/4 of a turn.
WARNING!
Make sure the flame does not go out
when you quickly turn the knob from
the maximum position to the
minimum position.
Electrical connection
• Do not pull the mains cable to disconnect
the appliance. Always pull the mains plug (if
applicable).
• The appliance must not be connected with
an extension cable, an adapter or a multiple
socket. There is a risk of fire.
• Do not let the power cable to heat up to a
temperature of more than 90° C. The cable
should be guided by means of clamps fixed
to the side of the cabinet, in order to avoid
any contact with the equipment beneath the
cooktop.
• Make sure that there is access to the mains
plug after the installation.
Electrical Requirements
Permanent electrical installation must agree
with the latest I.E.E. Regulations and local
Electricity Board regulations. For your own
safety the installation must be done by a
qualified electrician (e.g. your local Electricity
Board, or a contractor who is on the roll of the
National Inspection Council for Electrical
Installation Contracting [NICEIC]).
12
The manufacturer refuses to be
held responsible, if these safety
measures are not abided by.
Supply connections
This hob has to be connected to 220-240 V (~
50/60 Hz ) electricity supply.
The hob has a terminal block which is
marked as follows:
• L — Live terminal
• N — Neutral terminal
or E — Earth terminal
Before carrying out the connection, make sure:
1. The limiter valve and the electrical system
can take the appliance load (see the rating
plate)
2. The supply system is equipped with an
efficient earth connection in compliance
with the current standards and regulations
3. The outlet or omnipolar switch used for
connection is easily accessible with the
appliance installed.
The appliance is supplied with a 3 core flexible
power cable.
The wires in the cord are coloured as follows:
Green and yellow
Blue
Brown
WARNING!
A cut off plug inserted into a 13 amp
socket is a serious shock hazard.
Ensure that the cut off plug is
disposed of safely.
Replacement of the connection cable
The replacement of electric cable
must be carried out exclusively by
the service force centre or by
personnel with similar
competencies, in accordance with
the current regulations.
- Earth
- Neutral
- Live