KEMKRAFT KEI-095 Instructional Manual page 4

Brake pedal travel tester
Table of Contents

Advertisement

4.
The test screen will now be displayed.
The current data value is displayed under the Now column and the greatest positive or
negative peak value is displayed under the Peak column.
5.
With the engine on, the shift level in park, and your foot off the brake pedal, press the 0
key to Zero all values. The Brake tester will store the zero values until the unit is
switched off.
6.
While testing, the Peak value can be reset by pressing the 3 key at any time. This has
no effect on data storage or any other reading, it resets the displayed peak only.
7.
To begin data storage at any time press the 1 key. The first line of the test screen will
change to DATA-000, indicating that the brake tester is now collecting data. The
number will begin counting upward to indicate how much memory has been used. The
memory is full when the display reaches DATA-460.
To stop data collection at any time, press the 1 key again.
The start and stop time of each test (press of the 1 key) is recorded and stored in
memory to distinguish tests.
8.
Press the * key at any time to abort the test and return to the test menu. If data
collection is in progress, when the * key is pressed, the data collection will be stopped
and the data end time stamped with the current time.
96-002.doc
47650 CLIPPER DR. PLYMOUTH TWP., MI. 48170 (734) 414-6500
KEMKRAFT
MODEL KEI095/095A BRAKE PEDAL TESTER
Press 0 to ZERO all
Press 1 for DATA Co
Press 3 to Rst Peak
Press * to Abort
Pedal
Travel
Force
Decel
ENGINEERING, INC.
Now Peak
0.0
0.0
0.0
0.0
0.0
0.0
Page 4 of 9
Revised: 21-AUG-96