Trouble Shooting INSTALLATION INSTRUCTIONS Health & Safety Precautions Performance Specification Chimney Hearth & Fire Surround Central Heating Sytem System Controls Connection to Flues Soot Doors Thermostat Pre Lighting Check Commissioning Dimensions Parts Lists Certification Ref. Country 16BMF Issue F 06.13...
OPERATING INSTRUCTIONS ® Before lighting the stove check with the installer that the work or 50 mm in size). The coal should be dry. and checks described in the Installation Instructions have been When burning coal a little extra care is needed. Please take carried out correctly and that the chimney has been swept, is note of the section "Special Points For Burning Coal".
MULTIFUEL GRATE Light the stove using dry kindling wood and paper or fire Your Charnwood stove is fitted with a multifuel grate which lighters. Set the grate into either the wood or solid fuel enables both solid fuels and wood to be burned equally position as required.
OPERATING INSTRUCTIONS ® desired setting. sooty deposits should then be swept from the plate and into the fire. When burning wood use large logs rather than small ones. Proceed as above, but do not riddle the fire either when While the throat plate is lowered clean any sooty deposits shutting down or reviving.
OPERATING INSTRUCTIONS ® If the chimney previously served an open fire, it is possible that d) Wet wood or logs overhanging the front firebars will cause the higher flue gas temperature from the stove may loosen the glass to blacken.
Page 9
OPERATING INSTRUCTIONS ® e) A suitable fuel is being used. should then be cleaned. If the chimney fire does not go out when the above action is taken then the fire brigade should f) Door seals and airwash slide are intact.
PERFORMANCE In order for the appliance to perform satisfactorily the The rated output of the Country 16B Multifuel is 13.2 kW chimney height must not be less than 4 metres measured (45,040 Btu/h) to water and 6.4 kW (21,838 Btu/h) to the vertically from the outlet of the stove to the top of the room.
INSTALLATION INSTRUCTIONS ® room and also to prevent the fireplace from overheating. A less than 150 mm (6 inches) either square or round. This gap of 150mm (6 inches) each side and 300mm (12 inches) stove must not be used in a shared flue.
INSTALLATION INSTRUCTIONS ® Fig. 5. Typical Central Heating & Hot CENTRAL HEATING SYSTEM Water System Using 4 Boiler Tapping The central heating system must comply with BS:5449 part 1. 22mm Open Vents Feed and Expansion Tank Cold Water Tank...
INSTALLATION INSTRUCTIONS ® Fig 9. Horizontal Register Plate With Rear Flue Connection We recommend fitting a pipe thermostat onto the gravity return to act as a low limit thermostat. This should be wired Alternative into the mains supply to the pump so that if the gravity return...
COUNTRY 4 DIMENSIONS (MM) INSTALLATION INSTRUCTIONS ® ® Fig. 12 Flue Blanking Plate freely and easily when the riddling mechanism is operated. 2. The plates round the sides and back of the grate must be in Back of the Stove Blanking Plate position and sitting correctly.
COUNTRY 4 DIMENSIONS (MM) COUNTRY 16B MULTI FUEL DIMENSIONS (MM) ® ® Flue connection may be Top or Rear Boiler tappings are 1" BSP Female Optional Vertical Rear Flue Connector 509 558...
A.J WELLS & SONS LTD A.J WELLS & SONS LTD Bishops Way, Newport, Isle of Wight PO30 5WS, United Kingdom A Division of A.J.Wells & Sons Limited Registered in England No. 03809371 EN13240:2001 ROOMHEATERS & BOILER FIRED BY MULTI FUEL EC certificate of GS45-CPD-2009 conformity no:...
Page 20
BISHOPS WAY, NEWPORT, ISLE OF WIGHT PO30 5WS, UNITED KINGDOM T : + 4 4 ( 0 ) 1 9 8 3 5 3 7 7 7 7 • F : + 4 4 ( 0 ) 1 9 8 3 5 3 7 7 8 8 • C O N T A C T U S A T W W W . C H A R N W O O D . C O M ®...