INTRODUCTION
Little Giant Submersible 14S and 16S Series Sewage Ejector
Pumps and 14EH and 16EH Series Effluent Pumps are
recommended for use in basins or lift stations and suitable for
pumping sewage, effluent, wastewater and other non-explosive,
non-corrosive liquids. The S Series Sewage Ejector Pumps have
2" spherical solids handling capability. The EH Series Effluent
Pumps have 3/4" spherical solids handling capability.
Little Giant offers a complete line of float switches and liquid level
control systems for automatic operation along with a complete
line of alarms, basins, covers, and check valves.
UNPACKING
Little Giant pumps are carefully packaged, inspected and tested
to insure safe operation and delivery. When you receive your
pump, examine it carefully to determine that there are no broken
or damaged parts that may have occurred during shipment. If
damage has occurred, make notation and notify the firm from
which you purchased the pump and they will assist you in
replacement or repair, if required.
Figure 1
MODEL
LISTING
NO.
14EH-CIM
UL
14EH-CIM
UL
14S-CIM
UL
14S-CIM
UL
16EH-CIM
UL
16S-CIM
UL
16S-CIM
UL
NR: Not Recommended, operation at these heads or below will result in motor overload, reduced pump life and/or motor failure/damage.
14S-CIM
16S-CIM
14EH-CIM
16EH-CIM
AMPS/
HP
VOLTS
WATTS
1/2
115
12.5/1450
1/2
208-240
5.7/1275
1/2
115
11.6/1100
130
1/2
208-240
4.6/1100
130
1
230
9.0/2200
NR
1
230
11.0/1900
180
1
200-208
11.0/2000
180
DISCHARGE: 14EH & 16EH – 2", 14S – 2" or 3", 16S – 3".
HANDLING CAPABILITIES: EH Series – 3/4" spherical solids,
S Series – 2" spherical solids
HOUSING: Cast Iron
VOLUTE: Cast Iron
IMPELLER: Non-clog Cast Iron, with pressure relief vanes.
MOTOR: PSC, 3450 RPM (EH Series), 1625 RPM (S Series), with
automatic overload protection
HARDWARE: 300 series stainless steel
BEARING: Ball
SHAFT SEAL: Mechanical, spring loaded, rotating carbon with
Nitrile boot and stationary ceramic seat, with secondary Nitrile
exclusion seal
POWER CORD: 16 AWG 3-conductor copper stranded; 18 AWG
(208-240V models)
COOLING: The motor housing contains a cooling oil to provide
cooling for the motor and to lubricate bearings and seals. These
pumps are capable of operating with the motor housing partially
exposed for extended periods of time, providing sufficient motor
cooling and bearing lubrication, however, for the best cooling and
longest motor life, the liquid level being pumped should normally
be above the top of the cast iron motor housing.
PERFORMANCE GPM @ HEAD SHUTOFF
5'
10'
20'
30'
40'
NR
NR
60
40
20
NR
NR
60
40
20
100
35
100
35
NR
NR
90
70
160
100
40
160
100
40
SPECIFICATIONS
PWR
CORD
50'
60'
(Ft.)
P.S.I.
50
21.6
50
21.6
25
10.8
25
10.8
50
30
81
35.1
35
15.1
35
15.1
WEIGHT
(lbs.)
(ft.)
20
74
20
74
20
80
20
80
20
82
20
88
20
88
1

Advertisement

Table of Contents
loading

Summary of Contents for Little Giant 14S Series

  • Page 1 POWER CORD: 16 AWG 3-conductor copper stranded; 18 AWG (208-240V models) Little Giant offers a complete line of float switches and liquid level control systems for automatic operation along with a complete COOLING: The motor housing contains a cooling oil to provide line of alarms, basins, covers, and check valves.
  • Page 2: Safety Guidelines

    Installation mounted outside of the basin, and comply with the National instructions are included with all Little Giant switches and Electrical Code. Do not use the power cord for lifting the pump.
  • Page 3: Maintenance And Service

    Chart. If trouble cannot be located with these steps shown, settle in valve and prevent opening on start-up. consult your pump dealer or take pump to a Little Giant authorized service center. A gate valve should follow the check valve to allow periodic cleaning of the check valve or removal of the pump.
  • Page 4 Figure 4...
  • Page 5 REPLACEMENT PARTS MODEL/CATALOG NO. ITEM PART DESCRIPTION 114100 WIRE HANDLE 114051 COVER, HOUSING 903723 SCREW, 1/4-20 x 3/4” 921103 LOCK WASHER, 1/4” 902437 SCREW, #8-32 x 1/4” 921059 LOCK WASHER, #8 950500/ CAPACITOR, 20mfd, 950503 1.75” DIA/CLIP, 1.75” DIA. 950501/ CAPACITOR, 30mfd, 950503 1.75”...
  • Page 6: Troubleshooting

    TROUBLESHOOTING PROBLEM PROBABLE CAUSES CORRECTIVE ACTION Pump not plugged in. Plug in pump. Pump does not turn on. Circuit breaker shutoff or fuse removed. Turn on circuit breaker or replace fuse. NOTE: Before troubleshooting automatic control, check to see that pump operates Accumulation of trash on mercury float switch.
  • Page 7: Warranty Period

    Each of the above noted Little Giant products is guaranteed to be in are not part of the contract for sale. Seller’s and manufacturer’s onIy perfect condition when it leaves our factory. During the time periods obligation, and buyer’s only remedy, shall be the replacement and/...
  • Page 8 For technical assistance, please contact ....1-888-956-0000 www.LittleGiantPump.com CustomerService-WTS@fele.com Form 993302 - 09/29/2009 © 2009 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.