Wiegand Out to Access System (Card/PIN stored in Access System)
Reader Mode
Facility Code
Set D0 & D1 Output
Set Output Bit Length
PIN Output (5 Digits)
Set 4/8 Bit Burst Output
Alarm Configuration (D.H.O/F.E.)
Door Held Open (D.H.O.)
Door Forced Open (F.E.) 40 (0-99) #
4. WIRING CONNECTIONS FOR DC OR AC POWER
The CV-550SPK V3 keypad can be powered by either DC or AC power within a range of 10V – 28V. When wiring for DC power use
the red wire for positive and the black wire for ground. When wiring for AC power use the red wire (AC1) to one AC wire and light
green wire (AC2) to the other AC wire.
Note: Confirm you are using the light green wire and not the dark green Data 0 wire.
Wiring for DC Power (AC1 &
Camden Model: CV-550SPK V3
AC2
Light Green
AC1
RED
D_IN
BROWN
OPEN
YELLOW
GND
BLACK
NO
BLUE
COM
PURPLE
NC
ORANGE
Note: Connect corresponding power as shown above to prevent damage to the keypad.
G
N
) D
Not Used
+ve
Power
-ve
Supply
DC
10-28V
Camden Model: CX-TRP-612DC
Relay contacts
To trigger door
strike or
Maglock
CV-550SPK V3 WATERPROOF KEYPAD
Step 1) 03 0 #
(Enables data lines to be connected to an Access Controller)
Step 2) 60 (0-255) # (Must match Access Controller)
Step 3) 61 0 #
(Enables D0 & D1 Wiegand Output data format)
Step 4) 62 (26-66) # (Example of 26 bit: 62 26 #)
Step 5) 64 4 # (1–5-digit key + # key buffered output)
Step 6) 64 (0, 2) # (0 = 4 bit burst, 2 = 8 bit burst, confirm
with Access manufacturer)
35 (0-99) # The set time starts once the door is unlocked, then
it will generate the alarm if the door is not closed. Timing is in
minutes. Closing the door resets the alarm.
Door opened with no valid PIN or Card immediately triggers
an alarm.
Timing is in minutes. Master Programming Code resets alarm.
W
i r i
g n
for AC Power (AC1 & AC2)
Camden Model: CV-550SPK V3
Light Green
AC2
RED
AC1
D_IN
BROWN
YELLOW
OPEN
BLACK
GND
BLUE
NO
PURPLE
COM
NC
ORANGE
INSTAL L AT ION INS T RUCT IONS
Power
Supply
AC
10-28V
Camden Model: CX-TRP-4016
Not Used
Relay contacts
To trigger door
strike or
Maglock
Page 3 of 7