FH2G – Express Dryer
Installation, Operation and Maintenance Manual
• The diameter of the ducted tube should not be restricted less than 10" in diameter.
• Runs longer than 10' may require the use of a booster fan (not included) to ensure
pressure losses are overcome.
• An external self-closing louvre should be utilized to keep out pests and rain water.
• The use of legacy "square or rectangle" ducting is permitted, considering a minimum
dimension of 8" x 16".
OPERATING THE DRYING CABINET
STEP ONE
• Load gear or hose into the dryer.
• Close door(s) and secure latch.
Figure – Top Duct Guard
FIGURE: CONTROL PANEL
6 |
P a g e