Download Print this page

Advertisement

Quick Links

Exhaust and Transfer Fans
En gi neer i n g S i m p li c i t y i nto Ki tc hen Ve nt i l ati on Syste ms
EXHAUST AND TRA NSF ER FA NS
|
1

Advertisement

loading

Summary of Contents for Accurex XRUD

  • Page 1 Exhaust and Transfer Fans En gi neer i n g S i m p li c i t y i nto Ki tc hen Ve nt i l ati on Syste ms EXHAUST AND TRA NSF ER FA NS...
  • Page 2 It also means ventilation you you’re sourcing from one trusted provider. Just call or can rely on now and well into the future. email an Accurex representative and you’re on your way to a complete kitchen ventilation system. It’s that easy.
  • Page 3 D R I V E C F M P R ES S U R E PAG E Roof Upblast and Sidewall Direct 6,500 3 in. wg XRUD 4 - 1 2 Exhaust Fan, Galv/Alum Roof Upblast and Sidewall XCUE Direct 14,700 3 in. wg...
  • Page 4 Roof Upblast and Sidewall Exhaust...
  • Page 5: M Odel Nu Mbe R Co De

    ROO F UPBLAST AND S ID E WALL E X HAUST ROOF U P B L AST A N D SI DEWALL E X H AUST M OD E L OV ERV IE W Both, roof upblast and sidewall OFFE R T HE F OL LOW I N G BEN EFI TS : configuration, are specifically •...
  • Page 6 ROOF UPBL AST AND SI D E WA LL E X HAU ST M OD EL C O M PA R I SO N XRUD - Direct Drive Model XRUD galvanized/aluminum direct drive upblast centrifugal exhaust fans are specifically designed for roof or wall mounted applications.
  • Page 7 100,000 hours (L50 average life of 500,000 hours). protection on XCUE and XCUBE, sizes 099 through 300 and all sizes with UL/cUL 762. XRUD models utlize Motor – Carefully matched to the fan load and mounted leakproof brazed junction.
  • Page 8 ROOF UPBL AST EX HAU ST M OD EL C O M PA R I SO N STA NDARD CO N ST R UC T I ON FE AT URE S-X RU B S Shaft – Precisely sized, ground, and polished so the first Leakproof Construction –...
  • Page 9 OPTIO NS AND AC CE S SO R IE S WIN D BAND EXTENS IO N ROOF C U R B S Aluminum tube raises fan’s discharge an Wide variety of roof curbs additional 12"-54", depending on fan size for are available for mounting special code requirements.
  • Page 10 ROOF UPBL AST AND SI D E WA LL E X HAU ST OP TION S A ND AC C ESS OR I E S BI RD SC RE EN Rigid wire to protect the fan’s discharge from birds or small objects. CU RB SE AL Foam or high temperature seal between fan and curb to ensure proper sealing when attached to...
  • Page 11: Typical Installations

    TYPICAL INSTALLATI ON S COMME RC I AL K I TC H EN ( GR EAS E ) Sizes 099 and larger are designed to meet restaurant and food service applications. These fans are UL/cUL 762 Listed for grease removal and have been tested under high temperature [400°F (204°C)] and abnormal flare-up [600°F (316°C)] conditions.
  • Page 12 OP TIO N S GU IDE OPTION S AND ACC ESSO R IE S XCUBE XCUE XRUBS XRUD Roof Curbs Optional Optional Optional Optional Vented Curb Extensions Optional Optional Optional Optional Disconnect Switches Standard Standard Standard NEMA-3R Only Hinge Kit...
  • Page 13 Inline Fans Filtration Options INLINE FA NS...
  • Page 14 INL INE FANS MO DE L CO M PA R IS ON XID and XIB XIB AND XID MO D EL OV E RV IEW Designed for clean air applications (intake, • Centrifugal backward-inclined belt or direct drive fans exhaust, return, or make-up air systems), •...
  • Page 15 XTIF XTIF M OD EL OV ERV IE W Designed for ducted inline • Inline centrifugal fans installations, Accurex tubular centrifugal fans provide quiet, • Performance range: 300 to 26,000 cfm (500 to 44,200 m3/hr) efficient and reliable • Static pressure: Up to 4.0 in. wg (993 Pa) air performance.
  • Page 16 • Roof exhaust or supply (with weatherhood) XTIF - Inline Fan Model XTIF inline fan is the ideal choice for ducted systems. Accurex’s standard fan can be mounted in any position from horizontal to vertical, allowing installation in the smallest possible space, at the lowest installation cost.
  • Page 17 STAN DARD C ONSTRU CTIO N FE ATUR E S Cabinet Construction – The fan housing is constructed Bearings – 100% factory tested and designed specifically of rigid structural members and formed galvanized steel for air handling applications with a minimum L10 life in excess of 100,000 hours ( L 50 average life of panels.
  • Page 18 INL INE FANS STA NDA R D A ND OP T ION AL CON ST R U C T I O N F EAT U R E S XQEI - Inline Fan The XQEI inline fan has different wheel designs with different performance characteristics.
  • Page 19 XTIF - Inline Fan All XTIF inline fans are available in two levels of construction to provide the most efficient and economical selections. Construction differences between Level 1 and 2 selections include: the impeller, the inlet cone, the shaft size, and the bearings. The housings for both levels are identical in material gauge and overall design.
  • Page 20 • Inline grease exhaust fans should be installed near the end of the duct run to reduce sound at the hood. • Inline fan must be securely bolted to the exhaust duct per NFPA 96 guidelines. Accurex’s companion flanges are recommended for ease of installation.
  • Page 21 OPTIO NS AND AC CE S SO R IE S X ID, X I B , XQE I, AN D XT I F Belt Guard – Belt guards are totally enclosed to provide protection Dampers – Motorized parallel blade dampers (Model WD-330) from rotating pulleys and belts.
  • Page 22 INL INE FANS TYP I CAL IN STA LLATI ON OP TI ON S XI D AN D X I B SI DE D ISCH ARGE OPT I ON The side discharge option provides several advantages, from removing a system effect problem, increasing performance, or even reducing installation labor.
  • Page 23 Model SQ 1 in. 1 in. FILT E R B OXE S Model Material Approx Filter Qty . Size Thickness WT . (lbs.) Size The filter box is designed to provide a compact, convenient, 60-75 10x 12 and clean air solution. Factory-assembled as a single unit, this 80-95 15 11 14x 25...
  • Page 24 INL INE FANS TYP I CAL IN STA LLATI ON OP TI ON S XI D, XI B , XQE I , AN D XT I F I SOLATOR S Complete isolator kits are available with either neoprene or spring isolators and are sized to match the weight of the individual fan sizes.
  • Page 25 All XQEI and XTIF fans can be mounted vertically (ceiling hung or base mounted) for either upward or downward airflow. Optional mounting rails are recommended. Note: All fans are shown with optional vibration isolators. Contact your local Accurex representative for complete dimensional data. INLI NE FA NS...
  • Page 26 IN LIN E FANS OPT IO NS GU ID E OPTIO NS AND ACC E S SO R I E S XQEI XTIF Belt Guard – – Optional Optional Motor Cover (Weatherhood) Optional Optional Optional Optional Inlet and Outlet Companion Flanges Optional Optional Optional...
  • Page 27 Utility Fans Filtration Options UTIL I TY FA NS...
  • Page 28 C ENT RIFUGAL FAN AP P LI CATI ON S Restaurant Grease Exhaust (UL/cUL 762 Listed) R ESTAUR A NTS The centrifugal scroll fans are designed for high-pressure restaurant grease exhaust applications. Either Permalock™ or welded housings are available with UL/cUL Listing of Power Ventilators for Restaurant Exhaust Appliances.
  • Page 29 UTILITY FANS M OD E L CO M PAR IS ON XUEF M OD E L OV ERV IE W Provides higher operating • Backward-inclined utility fans efficiencies, non-overloading horsepower curves and • Housing and blower scroll options of galvanized, painted steel or aluminum higher pressure capabilities.
  • Page 30 UT ILITY FANS MOD E L CO M PAR I SON XUEF-100 The XUEF-100 is constructed from galvanized steel with a bolted frame. It provides an economical price point option for applications for when clean air is being exhausted. The XUEF-100 is available in both direct and belt drive configurations.
  • Page 31 UTIL ITY FANS STAN DA R D C ON STR UCTI ON F EAT U R E S XU EF -10 0, XU EF -30 0 & XU EF-50 0 XUE F- 10 0 STAN DAR D C O NSTR U CTIO N FEATURE S •...
  • Page 32 STAN DARD C ONSTRU C TIO N F E ATUR E S – X UE F D IR E CT D R I VE XUEF Direct Drive The XUEF direct drive model (100 series only) is an arrangement for utility set fan with a backward-inclined centrifugal wheel.
  • Page 33 OPTIO NS AND AC CE S SO R IE S UL/cUL 762 – The UL/cUL 762 option includes a Vibration Isolators – Neoprene or weatherhood, threaded drain connection and access spring isolators are available to door. Indoor mounting requires the fan to have welded lessen mechanical vibration and scroll construction.
  • Page 34: Mounting Options

    OP TIO N S AND ACC ESSO R I E S Mounting Options D I R E CT M OU NT No base required. Isolators are attached directly to equipment. Direct isolation can be used if equipment is unitary and rigid without the use of additional support.
  • Page 35 T YP I CAL INSTALL ATION - G ENE RAL CL EAN AIR OR FUME H O OD (N O N - GREASE) Accurex’s utility fans are designed for applications ranging from clean air to contaminated air. Typical installations for XUEF’s are shown below.
  • Page 36 UTIL ITY FANS OPT IO NS A ND ACC ES SOR I ES XUEF-100 XUEF-300 XUEF-500 OPTION S AND ACC ESSO R IE S UL/cUL 762 – Optional Optional UL/cUL 705 Optional Optional Optional Weatherhood Standard Standard Standard Drain Connection Standard Optional Optional...
  • Page 37 UTIL I TY FA NS...
  • Page 38 Roof Exhaust...
  • Page 39: M Odel Nu Mbe R Co De

    ROO F EX HAUST M O D E L OVE RVI EW At Accurex, we put our products through extensive life testing, assuring you M OD E L OV ERV IE W Accurex’s centrifugal roof exhaust that the fans will provide years of reliable performance. All fan sizes are tested fans provide the industry’s best...
  • Page 40 ROOF EXHAUST M OD E L C OM PA R IS ON XRED - Direct Drive Model XRED direct drive centrifugal fans are specifically designed for general clean air, roof mounted applications. Ideal for use with average duct runs and average-resistance duct, the XRED provides long service with little maintenance.
  • Page 41 STAN DARD C ONSTRU C TI O N F E ATUR ES X R E D AN D XR EB Wheel – Backward-inclined, non-overloading centrifugal wheel Vibration Isolation – True vibration isolators contain two is utilized to generate high efficiency and minimal sound. independent studs with rubber neoprene to support the drive Wheel cones are carefully matched to the venturi for maximum assembly and wheel for long life and quiet operation.
  • Page 42 ROOF EX HAUST O P TIO NS A ND ACC ES SOR I ES X R ED A ND X R EB Greenheck Vari-Green Motor Coatings– A wide variety of coatings and colors are available. ® Availability for direct drive fans Permatector™...
  • Page 43 Greenheck's electronically commutated EC Vari-Green (VG) motor combines motor technology, controllability and energy efficiency into one single low maintenance unit and is the industry’s first fully controllable motor. When combined with Accurex’s XRED fans, all the CFM and static pressure ranges of a belt drive can be attained. Features are: •...
  • Page 44 The system controls will lessen the amount of conditioned air that is exhausted, further reducing the total operating costs. For more detailed information refer to the Greenheck Vari-Green Motor brochure on accurex.com. A 0-10 VDC control signal may be used in conjunction with: •...
  • Page 45 OPTIO NS AND AC CE S SO R IE S X R E D AN D X R E B Roof Curbs – Prefabricated High Wind and Severe roof curbs reduce installation Duty Roof Curbs – time and costs by ensuring Provided as optional with models compatibility between the fan, XRED and XREB.
  • Page 46 ROOF EXHAUST TYPI CAL INSTALLATI ON X R ED A ND XR EB Models XREB and XRED exhaust fans are designed to meet the needs of general clean air applications. Tests were conducted to ensure safe, rugged and reliable fans. Disconnect Due to the varying airstreams encountered in commercial ventilation, system designers must be aware of national,...
  • Page 47 Ceiling and Filtration Options Cabinet Fans CEILING AND CAB INET FA NS...
  • Page 48 Great things come in small packages, as do our ceiling fans (model XCR) and MO DEL OV ERV IE W Accurex’s provides the cabinet fans (model XIR). Be assured when you buy any Accurex product; you most comprehensive ceiling are getting a quality product at a competitive price. We guarantee our ceiling and cabinet exhaust fan lines and cabinet fans with a three (3) year warranty.
  • Page 49 XC R FA NS AR E DES I G N ED FOR CEI L I NG M O U N TED AP P LICATIO NS. XI R FAN S A R E D ES I GN E D FOR I N LI N E R EMOTE M O U NTED AP PLICATIO NS. XCR-A The XCR-A is a premium ceiling fan.
  • Page 50 CEILING AN D CABI NE T FA NS STA NDAR D C ON ST R U C T I O N F EAT U R ES XC R -A Spring Loaded Aluminum Backdraft Damper – Mounting Brackets – Fully adjustable for multiple Eliminates rattling or unwanted backdrafts.
  • Page 51 STAN DARD C ONSTRU C TI O N F E ATUR ES XCR -B Mounting Brackets – Fully adjustable for multiple Plastic Backdraft Damper – Prevents installation types. unwanted backdrafts. Round Standard Outlet (6 in.) – Versatile for Housing – Embossed galvanized steel for rigidity and low profile for height restricted areas.
  • Page 52 CEILING AN D CABI NE T FA NS STA NDAR D C ON ST R U C T I O N F EAT U R ES XC R - C Plastic Backdraft Damper – Prevents Mounting Brackets – Adjustable for several unwanted backdrafts.
  • Page 53 STAN DARD C ONSTRU CTIO N FE ATUR E S X I R -A Spring Loaded Aluminum or Plastic Mounting Brackets – Fully adjustable for multiple Backdraft Damper – Eliminates rattling or installation conditions. unwanted backdrafts. Housing – Embossed galvanized steel for rigidity. Outlet –...
  • Page 54 CEILING AN D CABI NE T FA NS STA NDAR D CON STR U C T I ON F EAT U R ES X I R - B Aluminum or Plastic Backdraft Damper – Housing – Embossed galvanized steel for rigidity Prevents unwanted backdrafts.
  • Page 55 LIGHT OP T I ON S Accurex’s fan/light combination utilizes our LED panel grille. UL Listed for above bathtub/showers with GFCI branch protected circuit. Available on XCR-A Sizes 50 - 390, XCR-B Sizes 50-200.
  • Page 56 CEILING AN D CABI NE T FA NS OP T ION S AN D AC C ESS OR I E S XC R A ND XI R Model 6WSSC – For use with shaded pole and PSC SPE ED CON T ROL S motors.
  • Page 57 TI ME D EL AY S W I TCH Time delay switches save energy by automatically turning off equipment. They may be used with models XCR and XIR fans and fan/light combinations, for extended operating time of fan. Time delay switches act in the same manner as a standard switch, however, there is a delay of 10, 20, 30, and 60 minutes after the switch has been turned off.
  • Page 58 XCR Model LENGTH WIDTH HEIGHT A50 - A190 131/2 111/8 The Accurex XCR-A and XCR-B ceiling radiation B50 - B200 143/8 121/4 dampers are UL Classified, rated at three hours A200 - A390 fire resistance, and are available on all XCR-A...
  • Page 59 O PTIO N S A N D ACCE S SOR I E S XCR-A XCR-B XCR-C XIR-A XIR-B Grille Options Standard – – – – Electrical Wiring Feature Standard Optional – Standard – Vertical Discharge Optional Standard – Optional – Optional Optional Greenheck Vari-Green Motor...
  • Page 60 Roof Curbs...
  • Page 61 ROO F CU RBS M OD E L OVE RVI EW Accurex offers a wide variety of prefabricated roof curbs. Available roof M OD E L OV ERV IE W Reduce installation time and costs curbs include: flanged, straight-sided, canted, pitched, ridged, vented, by ensuring compatibility between and sound absorbing.
  • Page 62 GPFVP for pitched roofs and GPFVR is available for ridged (double pitched) roofs. They are designed for use with Accurex’s model XRUB, XRUBS or XRUD fan to provide the required 40-inch minimum discharge height above the roofline (per NFPA 96).
  • Page 63 Designed for use with an 8-inch high roof curb and Accurex’s model XRUB, XRUBS or XRUD fan to provide the required 40-inch minimum discharge height above the roof (per NFPA 96).
  • Page 64 P HO NE : 8 0 0.33 3 .1 4 00 | FAX : 7 1 5. 241 .61 9 1 AC CUR E X .COM Discover how simple the Accurex way can be at Accurex.com © 2021 Accurex, LLC...

This manual is also suitable for:

XcueXcubeXrubsXidXibXqei ... Show all