2.1 Operational limitations

The operation of the device must be carried out under the conditions of influencing
factors and taking into account the parameters of the controlled objects in accordance with
the agreed technical characteristics, and the device must also be used within the framework
of its technical characteristics.
The user who is familiar with the operating documentation for this device is allowed to
work with the device.
After transporting the device to the place of operation at a negative ambient temperature
and bringing it into a room with a positive temperature, in order to avoid failure due to
moisture condensation, keep the product in the package for at least 2 hours.
During storage, the Vibration Meter Pen must be in a packing container, the battery
charge must be at least 50%.

2.2 Preparing the device for use

Carry out an external examination of the device, make sure that there are no mechanical
damages. If there is any dirt, wipe the display and the housing of the device with a clean
cloth.
Before using the device, make sure that there is sufficient charge in the Vibration Meter
Pen. When the low battery indicator appears, which is located on the right side of the display,
you need to connect the device to a PC using a USB cable or to a charger
Note - When using the Vibration Meter Pen for the first time, it is necessary to conduct an
external examination of the device and, without turning it on, recharge it until the charge indicator is
full by connecting it to a PC using a USB cable. The battery charge level is shown on the right side of
the display. After that, 2-3 complete charge and discharge cycles of the battery should be performed.
Prepare the surface of the controlled object, it should be as clean, smooth, and free of
contamination as possible.

2.3 Using the device

2.3.1 Turning on

The device is switched on by short-term pressing of the "
can select the required operating mode of the Vibration Meter Pen.

2.3.2 Measurement modes

Switching between modes is carried out by pressing the "
in the following modes: vibration acceleration measurement mode (m / s
measurement mode (mm / s); vibration displacement measurement mode (mm); mode of the
ratio of peak acceleration and vibration speed.
Vibration acceleration measurement mode
Acceleration measurement is especially useful for localizing high frequency vibrations
and is therefore suitable for detecting faults in bearings and gearboxes. Acceleration is
measured in m / s².
Vibration velocity measurement mode

2 INTENDED USE

" button, after which you
" key. The device operates
2
); vibration speed